Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In PET, corrections for photon scatter and attenuation are essential for visual and quantitative consistency. MR attenuation correction (MRAC) is generally conducted by image segmentation and assignment of discrete attenuation coefficients, which offer limited accuracy compared with CT attenuation correction. Potential inaccuracies in MRAC may affect scatter correction, because the attenuation image (μ-map) is used in single scatter simulation (SSS) to calculate the scatter estimate. We assessed the impact of MRAC to scatter correction using 2 scatter-correction techniques and 3 μ-maps for MRAC. The tail-fitted SSS (TF-SSS) and a Monte Carlo-based single scatter simulation (MC-SSS) algorithm implementations on the Philips Ingenuity TF PET/MR were used with 1 CT-based and 2 MR-based μ-maps. Data from 7 subjects were used in the clinical evaluation, and a phantom study using an anatomic brain phantom was conducted. Scatter-correction sinograms were evaluated for each scatter correction method and μ-map. Absolute image quantification was investigated with the phantom data. Quantitative assessment of PET images was performed by volume-of-interest and ratio image analysis. MRAC did not result in large differences in scatter algorithm performance, especially with TF-SSS. Scatter sinograms and scatter fractions did not reveal large differences regardless of the μ-map used. TF-SSS showed slightly higher absolute quantification. The differences in volume-of-interest analysis between TF-SSS and MC-SSS were 3% at maximum in the phantom and 4% in the patient study. Both algorithms showed excellent correlation with each other with no visual differences between PET images. MC-SSS showed a slight dependency on the μ-map used, with a difference of 2% on average and 4% at maximum when a μ-map without bone was used. The effect of different MR-based μ-maps on the performance of scatter correction was minimal in non-time-of-flight F-FDG PET/MR brain imaging. The SSS algorithm was not affected significantly by MRAC. The performance of the MC-SSS algorithm is comparable but not superior to TF-SSS, warranting further investigations of algorithm optimization and performance with different radiotracers and time-of-flight imaging.

Download full-text PDF

Source
http://dx.doi.org/10.2967/jnumed.117.190231DOI Listing

Publication Analysis

Top Keywords

scatter correction
16
attenuation correction
12
scatter
11
scatter-correction techniques
8
single scatter
8
scatter simulation
8
mc-sss algorithm
8
mr-based μ-maps
8
pet images
8
large differences
8

Similar Publications

Abtract: PURPOSE: To evaluate the correlation between corneal backscatter and visual function in patients with Fuchs endothelial corneal dystrophy (FECD).

Study Design: Prospective case series.

Methods: This study included 53 eyes from 38 patients with FECD.

View Article and Find Full Text PDF

Purpose: To evaluate visual and refractive outcomes, visual quality, patient satisfaction, and spectacle independence 3 months after phacoemulsification with bilateral non-diffractive enhanced depth of focus (EDOF) lens implantation.

Methods: This study included 68 eyes of 34 consecutive patients, with 51.5% undergoing refractive lens exchange and 48.

View Article and Find Full Text PDF

Previous studies have suggested potential associations between some dietary factors and oral mucosal lesions (OMLs), however, existing research could be biased due to limited sample size and unaccounted confounding factors. This study aimed to explore the causal relationships between 13 common dietary factors and 3 OMLs using 2-sample Mendelian randomization (MR) analysis. Data for the MR analysis were extracted from publicly available genome-wide association study statistics.

View Article and Find Full Text PDF

Purpose: The combination of multi-layer flat panel detector (FPDT) X-ray imaging and physics-based material decomposition algorithms allows for the removal of anatomical structures. However, the reliability of these algorithms may be compromised by unaccounted materials or scattered radiation.

Approach: We investigated the two-material decomposition performance of a multi-layer FPDT in the context of 2D chest radiography without and with a 13:1 anti-scatter grid employed.

View Article and Find Full Text PDF

Pb-210 in volume samples: self-attenuation and scattering problems.

Appl Radiat Isot

September 2025

Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering (IFIN-HH), 30 Reactorului Str., PO Box MG-6, Magurele, Ilfov County, RO-077125, Romania. Electronic address:

In this work we study the effect of the matrix of the source on the spectrum and on the full energy peak efficiency for low energy photons. Using realistic simulations carried out with PENELOPE 2018, including detector resolution, we show that small angle Compton scattering does contribute to the peak count rate, implying the dependence of the matrix effects on the linear attenuation coefficient μ and also on the scattering cross section. We show that the effect of Compton scattering can be removed from the apparent peak, resulting a "clean" peak depending only on μ.

View Article and Find Full Text PDF