98%
921
2 minutes
20
Ex vivo machine perfusion (MP) is a promising way to better preserve livers prior to transplantation. Currently, no methodology has a verified benefit over simple cold storage. Before becoming clinically feasible, MP requires validation in models that reliably predict human performance. Such a model has been found in porcine liver, whose physiological, anatomical, and immunological characteristics closely resemble the human liver. Since the 1930s, researchers have explored MP as preservation, but only recently have clinical trials been performed. Making this technology clinically available holds the promise of expanding the donor pool through more effective preservation of extended criteria donor (ECD) livers. MP promises to decrease delayed graft function, primary nonfunction, and biliary strictures, which are all common failure modes of transplanted ECD livers. Although hypothermic machine perfusion (HMP) has become the standard for kidney ex vivo preservation, the precise settings and clinical role for liver MP have not yet been established. In research, there are 2 schools of thought: normothermic machine perfusion, closely mimicking physiologic conditions, and HMP, to maximize preservation. Here, we review the literature for porcine ex vivo MP, with an aim to summarize perfusion settings and outcomes pertinent to the clinical establishment of MP. Liver Transplantation 23 679-695 2017 AASLD.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/lt.24751 | DOI Listing |
Minerva Anestesiol
September 2025
Department of Cardiac, Thoracic and Vascular Surgery, Lithuanian University of Health Sciences, Kaunas, Lithuania.
Background: Postoperative cognitive dysfunction (POCD) occurs in 20% to 80% of patients following cardiac surgical interventions. The incidence of delirium is from 20% to 50%. Impaired cerebral autoregulation (CA) during cardiopulmonary bypass (CPB) contributes to these issues.
View Article and Find Full Text PDFExp Clin Transplant
August 2025
>From the Division of Transplant Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts; and the Sackler School of Medicine at Tel Aviv University, Tel Aviv, Israel.
Objectives: On-site normothermic machine perfusion of the liver may require hepatic arterial reconstruction. The effect of arterial reconstruction on the deve-lopment of primary ischemic cholangiopathy has not been fully elucidated in liver transplants with organs donated after circulatory death. The aim of this study was to evaluate the effect of normothermic machine perfusion with arterial reconstruction at the onset of ischemic cholangiopathy in liver transplants with organs donated after circulatory death.
View Article and Find Full Text PDFNat Rev Nephrol
September 2025
Nuffield Department of Surgical Sciences, University of Oxford, Oxford, UK.
The global shortage of suitable donor kidneys is the primary challenge in kidney transplantation, and it is exacerbated by ageing donors with increased numbers of health issues. Improving organ assessment, preservation and conditioning could enhance organ utilization and patient outcomes. Hypothermic machine perfusion (HMP) is associated with better results than static cold storage by reducing delayed graft function and improving short-term graft survival, especially in kidneys recovered from marginal-quality donors.
View Article and Find Full Text PDFPerfusion
September 2025
Department of Surgery, Columbia University, New York, NY, USA.
Static cold storage (SCS) on ice has remained the gold standard preservation method for heart transplantation, and prolonged cold ischemia outside the typical 4-6 hour window is associated with an increased risk of primary graft dysfunction - a consequence attributed to ischemic damage and reperfusion injury. This, unfortunately limits the travel radius for donor heart procurement, a key factor that contributes to the overall shortage of donor organs. Recent research and clinical data have illustrated the validity of other preservation systems in preserving cardiac allografts, and many of these devices have shown promise in potentially prolonging the tolerated ischemic time beyond the accepted standard.
View Article and Find Full Text PDFJ Cardiovasc Transl Res
September 2025
Department of Cardiac Surgery, University Hospital Halle (Saale), University of Halle, Ernst-Grube-Straße 40, 06120, Halle (Saale), Germany.
We compared the effects of ex-vivo machine perfusion (EVMP) of hearts donated after circulatory death (DCD) with the single-shot solutions HTK-N and Del Nido cardioplegia (DNC) on left-ventricular (LV) contractility and myocardial microcirculation. In a DCD pig model, hearts were maintained by EVMP with hypothermic, oxygenated HTK-N (DCD-HTK-N; N = 8) or DNC (DCD-DNC; N = 8) followed by reperfusion with blood, including assessment of contractility and microcirculation with Laser-Doppler-Flow (LDF). We performed transcriptomics using microarrays.
View Article and Find Full Text PDF