98%
921
2 minutes
20
Quantification of low molecular weight compounds (<800 Da) using matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI MS) is challenging due to the matrix signal interference at low m/z region and poor reproducibility of MS responses. In this study, a C60 labeling-MALDI MS strategy was proposed for the fast, sensitive and reliable determination of amino acids (AAs) in biofluids. An N-hydroxysuccinimide functionalized C60 was synthesized as the labeling reagent and added as an 880 Da tag to AAs; a carboxyl acid containing C60 was employed as the internal standards to normalize MS variations. This solved the inherent problems of MALDI MS for small molecule analysis. The entire analytical procedure-which consisted of simple protein precipitation and 10 min of derivatization in a microwave prior to the MALDI MS analysis-could be accomplished within 20 min with high throughput and great sample matrix tolerance. AA quantification showed good linearity from 0.7 to 70.0 μM with correlation coefficients (R) larger than 0.9954. The limits of detection were 70.0-300.0 fmol. Good reproducibility and reliability of the method were demonstrated by intra-day and inter-day precision with relative standard deviations less than 13.8%, and the recovery in biofluid ranged from 80.4% to 106.8%. This approach could be used in 1 μL of urine, serum, plasma, whole blood, and cerebrospinal fluid. Most importantly, the C60 labeling strategy is a universal approach for MALDI MS analysis of various LMW compounds because functionalized C60 is now available on demand.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aca.2017.01.018 | DOI Listing |
Anal Chim Acta
April 2020
Department of Chemistry, Wuhan University, Wuhan, 430072, PR China; Frontier Science Center for Immunology and Metabolism, Wuhan University, Wuhan, 430072, PR China. Electronic address:
Perturbation of thiol homeostasis in biological fluids are thought to be associated with several diseases, and reliable analytical methods for the determination of low molecular weight (LMW) thiols in human plasma or serum are thus required. In this study, a matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) method is described for high throughput determination of four LMW thiols (glutathione, cysteine, homocysteine and cysteinylglycine) in human serum. It is based on the use of a bromoacetyl functionalized C60 (Br-C60) as a derivatization reagent to label thiols.
View Article and Find Full Text PDFAnal Chim Acta
April 2017
Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072, PR China. Electronic address:
Quantification of low molecular weight compounds (<800 Da) using matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI MS) is challenging due to the matrix signal interference at low m/z region and poor reproducibility of MS responses. In this study, a C60 labeling-MALDI MS strategy was proposed for the fast, sensitive and reliable determination of amino acids (AAs) in biofluids. An N-hydroxysuccinimide functionalized C60 was synthesized as the labeling reagent and added as an 880 Da tag to AAs; a carboxyl acid containing C60 was employed as the internal standards to normalize MS variations.
View Article and Find Full Text PDFJ Control Release
August 2016
School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, PR China; Collaborative Innovation Center of New Drug Research and Safety Evaluation, Henan Province, PR China. Electronic address:
The traditional drug delivery systems always suffer from the unexpected drug release during circulation and the sluggish release of drug in target site. To address the problem, an "off-on" type drug delivery system with precise control was developed in this study. Doxorubicin (DOX) was covalently conjugated to fullerene (C60) nanoaggregates via a reactive oxygen species (ROS)-sensitive thioketal linker (C60-DOX NPs), and then the hydrophilic shell (Distearoyl-sn-glycero-3-phosphoethanolamine-PEG-CNGRCK2HK3HK11, DSPE-PEG-NGR) was attached to the outer surface of C60-DOX, giving it (C60-DOX-NGR NP) excellent stability in physiological solutions and active tumor-targeting capacity.
View Article and Find Full Text PDFACS Appl Mater Interfaces
April 2016
imec , Kapeldreef 75, B-3001, Leuven, Belgium.
Fullerene-based molecules are the archetypical electron-accepting materials for organic photovoltaic devices. A detailed knowledge of the degradation mechanisms that occur in C60 layers will aid in the development of more stable organic solar cells. Here, the impact of storage in air on the optical and electrical properties of C60 is studied in thin films and in devices.
View Article and Find Full Text PDFAnal Chim Acta
May 2015
Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS), Shandong Provincial Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, PR China. Electronic address: wqin
An all-solid-state polymeric membrane Pb(2+) ion-selective electrode (Pb(2+)-ISE) based on bimodal pore C60 (BP-C60) as solid contact has been developed. A BP-C60 film can be readily formed on the surface of a glassy carbon electrode by electrochemical deposition. Cyclic voltammetry and electrochemical impedance spectroscopy have been employed to characterize the BP-C60 film.
View Article and Find Full Text PDF