A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Determination of pesticides in fatty matrices using gel permeation clean-up followed by GC-MS/MS and LC-MS/MS analysis: A comparison of low- and high-pressure gel permeation columns. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Two low-pressure columns (Bio-Beads SX-3) and three high-pressure GPC columns were compared for clean-up of a wide range of pesticides in fatty matrices of vegetable or animal origin. The GPC fractions were analyzed by GC-MS/MS and LC-MS/MS without additional clean-up. The performance of the GPC clean-up on the five column types was compared in terms of solvent consumption, lipid removal, pesticide recovery and repeatability. It was found that for fatty matrices, mainly consisting of high molecular weight triglycerides i.e. most vegetable oils and animal fats, good fractionation is obtained for the majority of the pesticides. On the other hand, for fats and oils containing relatively high amounts of low molecular weight triglycerides, i.e. butter fat and palm kernel oil, none of the columns provided sufficient clean-up and cause interferences and system contamination, especially in the case of GC-MS/MS analysis. For the latter case, best results in terms of lipid removal and pesticide recovery were obtained on a set (2×300mmlength) of narrow bore (7.5mm ID) columns packed with 5µm PL Gel material. Column loadability is, however, much lower on that set of columns compared the other evaluated GPC columns, impairing overall method sensitivity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2016.12.032DOI Listing

Publication Analysis

Top Keywords

fatty matrices
12
pesticides fatty
8
gel permeation
8
gc-ms/ms lc-ms/ms
8
gpc columns
8
columns compared
8
lipid removal
8
removal pesticide
8
pesticide recovery
8
molecular weight
8

Similar Publications