Background: In the past few years, the artificial pancreas-the commonly accepted term for closed-loop control (CLC) of blood glucose in diabetes-has become a hot topic in research and technology development. In the summer of 2014, we initiated a 6-month trial evaluating the safety of 24/7 CLC during free-living conditions.

Research Design And Methods: Following an initial 1-month Phase 1, 14 individuals (10 males/4 females) with type 1 diabetes at three clinical centers in the United States and one in Italy continued with a 5-month Phase 2, which included 24/7 CLC using the wireless portable Diabetes Assistant (DiAs) developed at the University of Virginia Center for Diabetes Technology. Median subject characteristics were age 45 years, duration of diabetes 27 years, total daily insulin 0.53 U/kg/day, and baseline HbA1c 7.2% (55 mmol/mol).

Results: Compared with the baseline observation period, the frequency of hypoglycemia below 3.9 mmol/L during the last 3 months of CLC was lower: 4.1% versus 1.3%, P < 0.001. This was accompanied by a downward trend in HbA1c from 7.2% (55 mmol/mol) to 7.0% (53 mmol/mol) at 6 months. HbA1c improvement was correlated with system use (Spearman r = 0.55). The user experience was favorable with identified benefit particularly at night and overall trust in the system. There were no serious adverse events, severe hypoglycemia, or diabetic ketoacidosis.

Conclusion: We conclude that CLC technology has matured and is safe for prolonged use in patients' natural environment. Based on these promising results, a large randomized trial is warranted to assess long-term CLC efficacy and safety.

Download full-text PDF

Source
http://dx.doi.org/10.1089/dia.2016.0333DOI Listing

Publication Analysis

Top Keywords

closed-loop control
8
6-month trial
8
24/7 clc
8
feasibility long-term
4
long-term closed-loop
4
control multicenter
4
multicenter 6-month
4
trial 24/7
4
24/7 automated
4
automated insulin
4

Similar Publications

We study the elementary problem of moving an active particle by a trap with minimum work input. We show analytically that (open-loop) optimal protocols are not affected by activity, but work fluctuations are always increased. For closed-loop protocols, which rely on initial measurements of the self-propulsion, the average work has a minimum for a finite persistence time.

View Article and Find Full Text PDF

Precise delivery of nanoliter-scale reagents is essential for high-throughput biochemical assays, yet existing platforms often lack real-time control and selective content fusion. Conventional methods rely on passive encapsulation or stochastic pairing, limiting both throughput and biochemical specificity. Here, we introduce an on-demand nanoliter delivery platform that seamlessly integrates electrical sensing, triggered droplet merging, and passive sorting in a single continuous flow.

View Article and Find Full Text PDF

Subthalamic deep brain stimulation (STN-DBS) provides unprecedented spatiotemporal precision for the treatment of Parkinson's disease (PD), allowing for direct real-time state-specific adjustments. Inspired by findings from optogenetic stimulation in mice, we hypothesized that STN-DBS can mimic dopaminergic reinforcement of ongoing movement kinematics during stimulation. To investigate this hypothesis, we delivered DBS bursts during particularly fast and slow movements in 24 patients with PD.

View Article and Find Full Text PDF

Updates on Parkinson's Disease.

Neuropsychiatr Dis Treat

September 2025

Department of Radiology, No. 926 Hospital, Joint Logistics Support Force of PLA, Kaiyuan, Yunnan, 661699, People's Republic of China.

Parkinson's disease (PD) represents a progressive neurodegenerative disorder with escalating global burden, with mechanistic studies revealing α-synuclein propagation through gut-brain axis, mitochondrial defects, and neuroinflammatory cascades driven by genetic-environmental interplay. Recent advancements in diagnostic paradigms have successfully combined α-synuclein seed amplification assays with multimodal neuroimaging techniques, achieving an impressive diagnostic accuracy of 92% during the prodromal stages of disease. Phase II trials highlight disease-modifying potential of α-synuclein-targeting immunotherapies (40% reduction in motor decline) and LRRK2 kinase inhibitors showing blood-brain barrier penetration.

View Article and Find Full Text PDF

Management of diabetes mellitus in hemodialysis is highly complex due to increased glycemic variability and hypoglycemic risk. The use of technologies applied to diabetes has been shown to improve glycemic control, however data in dialysis patients are limited. To describe the efficacy and safety of the minimed 780G AHCL system in a stable hemodialysis patient and during hospitalization in the Intensive Care Unit (ICU).

View Article and Find Full Text PDF