Article Abstract

Background: Because of the commonality of diagnostic magnetic resonance imaging (MRI), MRI conditional technology has increased throughout the device industry. It is often difficult to be aware of MRI specifications for each device.

Objectives: We provide a review of the clinical experience with MRI and spinal cord stimulation (SCS) devices and develop a general reference of current device/MRI specifications.

Methods: We reviewed the available literature on the clinical experience with SCS devices and examined its specifications.

Results: We developed a user-friendly table of the specific compatibility of SCS devices in the USA and the European Union, and examined the existing literature on the clinical experience with MRI and SCS devices. We share our experience with obtaining spine MRI with MRI conditional SCS leads.

Conclusion: By describing SCS device specifications and reviewing the literature, we provide a guide to implanting and treating physicians on obtaining MRIs in patients who have SCS devices.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000448764DOI Listing

Publication Analysis

Top Keywords

scs devices
20
clinical experience
12
mri
8
spinal cord
8
cord stimulation
8
mri mri
8
mri conditional
8
experience mri
8
literature clinical
8
scs
7

Similar Publications

Static cold storage (SCS) on ice has remained the gold standard preservation method for heart transplantation, and prolonged cold ischemia outside the typical 4-6 hour window is associated with an increased risk of primary graft dysfunction - a consequence attributed to ischemic damage and reperfusion injury. This, unfortunately limits the travel radius for donor heart procurement, a key factor that contributes to the overall shortage of donor organs. Recent research and clinical data have illustrated the validity of other preservation systems in preserving cardiac allografts, and many of these devices have shown promise in potentially prolonging the tolerated ischemic time beyond the accepted standard.

View Article and Find Full Text PDF

Mapping between chain configuration and mechanical properties of poly(L-lactic acid) monofilaments via hydrolysis induction.

J Mech Behav Biomed Mater

August 2025

School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacturing of Precision Medicine Equipment, Southeast University, Nanjing, 211189, China. Electronic address:

Poly(L-lactic acid) (PLLA), as a substrate material, has been widely utilized in the field of biodegradable vascular stents. Prior to implantation, it is particularly crucial for these devices to assess the relationship of the mechanical properties and microstructures during full degradation cycle. Although previous studies have primarily focused on structural parameters such as crystallinity and molecular weight, there are relatively few reports that explore the impact of microstructure on mechanical performance from the perspective of chain configuration during the degradation.

View Article and Find Full Text PDF

Purpose: The analgesic mechanisms and neurophysiological effects of spinal cord stimulation (SCS) and dorsal root ganglion stimulation (DRGS) are poorly understood. In this pilot repeated-measures study, we used quantitative sensory testing (QST) and self-reported questionnaires to investigate the effects of these therapies in chronic pain patients from pre-implantation up to one-year post-implantation. Several studies have reported stimulation-induced effects on QST, potentially clarifying how neurostimulation affects the nervous system, which is poorly understood.

View Article and Find Full Text PDF

Purpose: Suprachoroidal (SC) drug delivery is a promising avenue for treating posterior segment ocular diseases. Current ex vivo models, primarily human cadaveric eyes, are limited by tissue variability and altered post-mortem fluid dynamics. We introduce near-real surgical specimens (NRSS), an engineered ocular tissue platform, to overcome these limitations and provide standardized, reproducible evaluation of SC drug delivery.

View Article and Find Full Text PDF

Objective: Introduced in 1970s, Spinal Cord Stimulator (SCS) devices have played a crucial role in managing a wide range of complex and refractory chronic pain, particularly back/leg pain as well as neuropathic pain. Currently, two primary types of leads, cylindrical and paddle leads, are prevalent in pain management. While both effectively alleviate pain, cylindrical leads, due to their small size, are susceptible to movement and migration as well as a smaller surface area for coverage, leading to device displacement and failure to provide pain relief.

View Article and Find Full Text PDF