98%
921
2 minutes
20
Noise exposure and hearing thresholds of indoor hockey officials of the Western States Hockey League were measured to assess the impact of hockey game noise on hearing sensitivity. Twenty-nine hockey officials who officiated the league in an arena in southeastern Wyoming in October, November, and December 2014 participated in the study. Personal noise dosimetry was conducted to determine if officials were exposed to an equivalent sound pressure level greater than 85 dBA. Hearing thresholds were measured before and after hockey games to determine if a 10 dB or greater temporary threshold shift in hearing occurred. Pure-tone audiometry was conducted in both ears at 500, 1000, 2000, 3000, 4000, 6000, and 8000 Hz. All noise exposures were greater than 85 dBA, with a mean personal noise exposure level of 93 dBA (SD = 2.2), providing 17.7% (SD = 6.3) of the officials' daily noise dose according to the OSHA criteria. Hearing threshold shifts of 10 dB or greater were observed in 86.2% (25/29) of officials, with 36% (9/25) of those threshold shifts equaling 15 dB or greater. The largest proportion of hearing threshold shifts occurred at 4000 Hz, comprising 35.7% of right ear shifts and 31.8% of left ear shifts. The threshold shifts between the pre- and post-game audiometry were statistically significant in the left ear at 500 (p=.019), 2000 (p=.0009), 3000 (p<.0001) and 4000 Hz (p=.0002), and in the right ear at 2000 (p=.0001), 3000 (p=.0001) and 4000 Hz (p<.0001), based on Wilcoxon-ranked sum analysis. Although not statistically significant at alpha = 0.05, logistic regression indicated that with each increase of one dB of equivalent sound pressure measured from personal noise dosimetry, the odds of a ≥ 10 dB TTS were increased in the left ear at 500 (OR=1.33, 95% CI 0.73-2.45), 3000 (OR=1.02, 95% CI 0.68-1.51), 4000 (OR=1.26, 95% CI 0.93-1.71) and 8000 Hz (OR=1.22, 95% CI 0.76-1.94) and in the right ear at 6000 (OR=1.03, 95% CI 0.14-7.84) and 8000 Hz (OR=1.29, 95% CI 0.12-13.83). These findings suggest that indoor hockey officials are exposed to hazardous levels of noise, experience temporary hearing loss after officiating games, and a hearing conservation program is warranted. Further temporary threshold shift research has the potential to identify officials of other sporting events that are at an increased risk of noise-induced hearing loss.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/15459624.2016.1225158 | DOI Listing |
Am J Ind Med
September 2025
National Institute for Occupational Safety and Health, Division of Field Studies and Engineering, Cincinnati, Ohio, USA.
Background: Workers in industry settings are often exposed to complex noise, which poses a greater risk to hearing loss than continuous noise at equivalent energy levels. Previous studies have identified kurtosis as an essential metric for evaluating complex noise-induced hearing loss (NIHL). This study aimed to characterize the distribution of workers exposed to complex noise, examine the associations between kurtosis and changes in hearing thresholds at various frequencies, and explore kurtosis's role in estimating NIHL and its integration into occupational hearing loss prevention programs.
View Article and Find Full Text PDFJ Neurol
September 2025
SENSE Research Unit, Department of Clinical and Movements Neurosciences, UCL Institute of Neurology, 33 Queen Square, London, WC1N 3BG, UK.
Positional nystagmus is a frequently encountered yet often underappreciated clinical sign that provides critical insights into vestibular and central nervous system function. For the general neurologist, recognising and correctly interpreting positional nystagmus can significantly impact diagnostic accuracy and guide appropriate management of common and complex dizziness presentations. The current diagnostic framework for positional nystagmus disproportionately favours BPPV, underestimates central positional nystagmus (CPN), and over-relies on imaging.
View Article and Find Full Text PDFRespir Physiol Neurobiol
September 2025
Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital Dallas, Dallas, TX, USA; Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, TX, USA. Electronic address: DrTonyBabb@TexasHeal
We examined the exercise ventilatory response to heavy exercise (ventilation [V̇] and carbon dioxide elimination [V̇CO] relationship from ventilatory threshold to peak exercise) and operational lung volumes (end expiratory [EELV] and end inspiratory [EILV]) in older adults with and without obesity. Forty-nine older adults with (BMI: 33.9 ± 5.
View Article and Find Full Text PDFACS Appl Mater Interfaces
September 2025
Department of Material Sciences and Engineering, Seoul National University, Seoul 08826, Republic of Korea.
A nanometer-scale multilayer gate insulator (GI) engineering strategy is introduced to simultaneously enhance the on-current and bias stability of amorphous InGaZnO thin-film transistors (a-IGZO TFTs). Atomic layer deposition supercycle modifications employ alternating layers of AlO, TiO, and SiO to optimize the gate-oxide stack. Each GI material is strategically selected for complementary functionalities: AlO improves the interfacial quality at both the GI/semiconductor and GI/metal interfaces, thereby enhancing device stability and performance; TiO increases the overall dielectric constant; and SiO suppresses leakage current by serving as a high-energy barrier between AlO and TiO.
View Article and Find Full Text PDFJ Acoust Soc Am
September 2025
School of Ocean Engineering and Technology, Sun Yat-sen University, Zhuhai 519000, China.
This study establishes a quantitative framework using field observations and normal mode theory to reveal wind field control mechanisms over ambient noise vertical directionality in shallow water. Acoustic data from a vertical line array in the northern South China Sea, combined with sound speed profiles, seabed properties, and multi-source wind fields (ERA5 reanalysis/Weibull-distributed synthetics), demonstrate: (1) A 20-km spatial noise-energy threshold (>90% energy contribution), challenging conventional near-field assumptions (1-2 km); (2) frequency-dependent distribution: low-frequency (50-200 Hz) directionality depends on near-field sources, while high-frequency (>400 Hz) energy shifts seaward due to modal cutoff variations; (3) model validation shows 0.96 correlation at 100 Hz/100 km (stratified medium accuracy), but seabed interface waves induce 3.
View Article and Find Full Text PDF