Feasibility of a walking virtual reality system for rehabilitation: objective and subjective parameters.

J Neuroeng Rehabil

Servicio de Neurorrehabilitación y Daño Cerebral de los Hospitales NISA, Fundación Hospitales NISA, Río Tajo 1, 46011, Valencia, Spain.

Published: August 2016


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Even though virtual reality (VR) is increasingly used in rehabilitation, the implementation of walking navigation in VR still poses a technological challenge for current motion tracking systems. Different metaphors simulate locomotion without involving real gait kinematics, which can affect presence, orientation, spatial memory and cognition, and even performance. All these factors can dissuade their use in rehabilitation. We hypothesize that a marker-based head tracking solution would allow walking in VR with high sense of presence and without causing sickness. The objectives of this study were to determine the accuracy, the jitter, and the lag of the tracking system and its elicited sickness and presence in comparison of a CAVE system.

Methods: The accuracy and the jitter around the working area at three different heights and the lag of the head tracking system were analyzed. In addition, 47 healthy subjects completed a search task that involved navigation in the walking VR system and in the CAVE system. Navigation was enabled by natural locomotion in the walking VR system and through a specific device in the CAVE system. An HMD was used as display in the walking VR system. After interacting with each system, subjects rated their sickness in a seven-point scale and their presence in the Slater-Usoh-Steed Questionnaire and a modified version of the Presence Questionnaire.

Results: Better performance was registered at higher heights, where accuracy was less than 0.6 cm and the jitter was about 6 mm. The lag of the system was 120 ms. Participants reported that both systems caused similar low levels of sickness (about 2.4 over 7). However, ratings showed that the walking VR system elicited higher sense of presence than the CAVE system in both the Slater-Usoh-Steed Questionnaire (17.6 ± 0.3 vs 14.6 ± 0.6 over 21, respectively) and the modified Presence Questionnaire (107.4 ± 2.0 vs 93.5 ± 3.2 over 147, respectively).

Conclusions: The marker-based solution provided accurate, robust, and fast head tracking to allow navigation in the VR system by walking without causing relevant sickness and promoting higher sense of presence than CAVE systems, thus enabling natural walking in full-scale environments, which can enhance the ecological validity of VR-based rehabilitation applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4977644PMC
http://dx.doi.org/10.1186/s12984-016-0174-1DOI Listing

Publication Analysis

Top Keywords

walking system
16
system
13
head tracking
12
sense presence
12
cave system
12
virtual reality
8
walking
8
presence
8
accuracy jitter
8
tracking system
8

Similar Publications

Background: Survivors of critical illness frequently face physical, cognitive and psychological impairments after intensive care. Sensorimotor impairments potentially have a negative impact on participation. However, comprehensive understanding of sensorimotor recovery and participation in survivors of critical illness is limited.

View Article and Find Full Text PDF

Neuroprostheses capable of providing Somatotopic Sensory Feedback (SSF) enables the restoration of tactile sensations in amputees, thereby enhancing prosthesis embodiment, object manipulation, balance and walking stability. Transcutaneous Electrical Nerve Stimulation (TENS) represents a primary noninvasive technique for eliciting somatotopic sensations. Devices commonly used to evaluate the effectiveness of TENS stimulation are often bulky and main powered.

View Article and Find Full Text PDF

The primary purpose of this study was to determine the preoperative predictors of gait biomechanics 6 months after unilateral total knee arthroplasty (TKA). There were 126 participants (age 64.4 ± 7.

View Article and Find Full Text PDF

Many behaviours which promote sleep overlap with the reported benefits of pet ownership. Research on pet ownership and sleep has predominately focused on co-sleeping with pets, leaving other pet ownership factors largely unexamined. The present study aimed to examine the relation between pet ownership and sleep as well as moderators and mediators of this relation.

View Article and Find Full Text PDF

Heartbeat detection and personal authentication using a 60 GHz Doppler sensor.

Front Digit Health

August 2025

Architecture Laboratory, Graduate School of Science, Technology and Innovation, Kobe University, Kobe, Japan.

Background: Microwave Doppler sensors, capable of detecting minute physiological movements, enable the measurement of biometric information, such as walking patterns, heart rate, and respiration. Unlike fingerprint and facial recognition systems, they offer authentication without physical contact or privacy concerns. This study focuses on non-contact seismocardiography using microwave Doppler sensors and aims to apply this technology for biometric authentication.

View Article and Find Full Text PDF