Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Applying peripheral venous lactate instead of arterial lactate in clinical practice is questionable because of deviation between both values. We aimed to find the relationship between the arterial lactate and the peripheral venous lactate before reasoned that the venous lactate could be used in substitution to the arterial lactate in sepsis.

Methods: We conducted a prospective, cross-sectional study at a university hospital. The patients with sepsis in ICU who required lactate level monitoring were enrolled in this research. The correlation and agreement between arterial lactate (A-LACT) and peripheral venous lactate (V-LACT) were the primary outcomes.

Results: A total of 63 paired samples were collected. The A-LACT and V-LACT were strongly correlated ( r = .934, P < .0001, r = .873). The regression equation was A-LACT = (0.934 × V-LACT) - 0.236. The mean difference between V-LACT and A-LACT was 0.66 ± 1.53 mmol/L. The 95% limits of agreement were between -3.66 and 2.33 mmol/L. The V-LACT ≥ 4 mmol/L can predict A-LACT level ≥ 4 mmol/L with 87.5% sensitivity and 91.5% specificity, and the area under receiver operating characteristic curve was 0.948.

Conclusion: The present study demonstrated a strong correlation between A-LACT and V-LACT, but an agreement between both parameters was poor. We suggest not to use the V-LACT in substitution to the A-LACT in sepsis regarding the absolute value and clearance rate, but the V-LACT ≥ 4.5 mmol/L may be used for predicting the A-LACT ≥ 4 mmol/L.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0885066616663169DOI Listing

Publication Analysis

Top Keywords

arterial lactate
20
venous lactate
20
≥ mmol/l
16
peripheral venous
12
lactate
11
patients sepsis
8
a-lact
8
v-lact
8
a-lact v-lact
8
v-lact ≥
8

Similar Publications

Background: Previous trials have demonstrated increased 5-year risks for adverse clinical events after coronary artery implantation of poly-l-lactic acid-based bioresorbable scaffolds (BRS) compared with cobalt chromium (CoCr) everolimus-eluting stents (EES).

Objectives: The aim of this study was to evaluate the 5-year clinical outcomes of the novel sirolimus-eluting NeoVas BRS compared with CoCr EES.

Methods: A total of 560 patients with single de novo native coronary artery lesions with reference vessel diameter 2.

View Article and Find Full Text PDF

Sepsis remains a leading cause of critical illness and mortality worldwide, driven by a dysregulated host response to infection and often complicated by persistent tachycardia and cardiovascular dysfunction. Increasing evidence implicates excessive sympathetic activation as a contributor to sepsis-related hemodynamic instability and myocardial injury, prompting growing interest in the use of β-adrenergic blockade as a therapeutic adjunct. This review synthesizes current data on the safety and efficacy of short-acting, cardioselective β-blockers (BBs), particularly esmolol and landiolol, in septic shock.

View Article and Find Full Text PDF

Introduction: Sepsis remains a leading cause of mortality, with mortality from septic shock exceeding 40%. Standardized resuscitation (30 mL/kg) may cause adverse outcomes, including fluid overload or prolonged hypotension, emphasizing the need for individualized strategies. Sepsis-induced shock arises from varying degrees of vasodilation and hypovolemia, yet patients often present with similar clinical signs in the emergency department (ED).

View Article and Find Full Text PDF

Background: The relationship between carbon dioxide pressures (PCO) and contents (CCO) is linked to the Haldane effect. Nevertheless, under shock conditions, hydrogen ion accumulation might strongly influence the discrepancies between PCO and CCO. This study aims to evaluate the impact of hydrogen ion accumulation and hemoglobin oxygen saturation (Haldane effect) on PCO:CCO relationships during induction and resuscitation of endotoxemic shock.

View Article and Find Full Text PDF

The carotid body mediates peak oxygen uptake during maximal physical exertion in rats.

J Physiol

September 2025

Instituto de Ciencias Biomédicas, Facultad de Ciencias de la Salud, Universidad Autónoma de Chile, Santiago, Chile.

Cardiorespiratory responses to physical exercise are expected to meet the organism's metabolic demands. As carotid body (CB) glomus cells have been proposed as metabolic sensors, we sought to determine their contribution to peak oxygen uptake ( ) during exercise in rats. Adult male Wistar Kyoto rats underwent bilateral co-injection of two adeno-associated viruses (AAVs) at the CB bifurcation (AVV-TH-Cre-SV40 and AVV-hSyn-DREADD(Gi)-mCherry).

View Article and Find Full Text PDF