98%
921
2 minutes
20
Due to various applications of human motion capture techniques, developing low-cost methods that would be applicable in nonlaboratory environments is under consideration. MEMS inertial sensors and Kinect are two low-cost devices that can be utilized in home-based motion capture systems, e.g., home-based rehabilitation. In this work, an unscented Kalman filter approach was developed based on the complementary properties of Kinect and the inertial sensors to fuse the orientation data of these two devices for human arm motion tracking during both stationary shoulder joint position and human body movement. A new measurement model of the fusion algorithm was obtained that can compensate for the inertial sensors drift problem in high dynamic motions and also joints occlusion in Kinect. The efficiency of the proposed algorithm was evaluated by an optical motion tracker system. The errors were reduced by almost 50% compared to cases when either inertial sensor or Kinect measurements were utilized.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1115/1.4034170 | DOI Listing |
J Neuroeng Rehabil
September 2025
Institute for Neuromodulation and Neurotechnology, University Hospital and University of Tübingen, 72076, Tübingen, Germany.
Innovative technology allows for personalization of stimulation frequency in dual-site deep brain stimulation (DBS), offering promise for challenging symptoms in advanced Parkinson's disease (PD), particularly freezing of gait (FoG). Early results suggest that combining standard subthalamic nucleus (STN) stimulation with substantia nigra pars reticulata (SNr) stimulation may improve FoG outcomes. However, patient response and the optimal SNr stimulation frequency vary.
View Article and Find Full Text PDFFront Neurol
August 2025
Department of Neurology, Charité-Universitätsmedizin Berlin, Berlin, Germany.
Background: Gait deficits and leg spasticity are frequent symptoms in Primary and Secondary Progressive Multiple Sclerosis (PPMS and SPMS). Transcutaneous spinal cord stimulation (tSCS) may alleviate these symptoms through the reduction of spinal hyperexcitability. We conducted a single-center, randomized, sham-controlled clinical crossover study (German Clinical Trials Register: DRKS00023357, https://www.
View Article and Find Full Text PDFSleep Med Rev
August 2025
Department of Pediatrics, Joan C. Edwards School of Medicine, Marshall University, Huntington, WV, USA.
Pediatric obstructive sleep apnea (OSA) is a common yet often underdiagnosed condition, partly due to limited access to polysomnography. Mandibular jaw movement (MJM) analysis offers a promising alternative to conventional home sleep apnea testing in children, capturing the dynamic interactions between respiratory drive and upper airway musculature, enabling accurate identification of, and critical insights into, sleep-disordered breathing events. This technical and practical review provides a structured framework for understanding and interpreting MJM signals during sleep in pediatric patients.
View Article and Find Full Text PDFJ Med Internet Res
September 2025
Department of Microsurgery, Orthopedic Trauma and Hand Surgery, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Background: Shoulder pain is a highly prevalent musculoskeletal disorder that severely compromises patients' quality of life. The Constant-Murley Scale (CMS) is a well-established method for shoulder function evaluation. However, the necessity of clinician involvement constrains its utility in continuous monitoring.
View Article and Find Full Text PDFJ Appl Biomech
September 2025
Department of Human Movement Science, University Medical Center Groningen, Groningen, The Netherlands.
Inertial Measurement Units (IMUs) enable accurate estimation of anatomical joint angles but require a sensor-to-segment calibration. Literature has presented several algorithms that address this gap; however, adequately comparing calibration performance is not trivial. This study compares 3 calibration methods: N-pose calibration (NP), functional calibration (FC), and manual alignment (MA) to estimate 3D wrist joint angles during single-plane and multiplane tasks.
View Article and Find Full Text PDF