98%
921
2 minutes
20
Current late gadolinium enhancement (LGE) imaging of left atrial (LA) scar or fibrosis is relatively slow and requires 5-15min to acquire an undersampled (R=1.7) 3D navigated dataset. The GeneRalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) based parallel imaging method is the current clinical standard for accelerating 3D LGE imaging of the LA and permits an acceleration factor ~R=1.7. Two compressed sensing (CS) methods have been developed to achieve higher acceleration factors: a patch based collaborative filtering technique tested with acceleration factor R~3, and a technique that uses a 3D radial stack-of-stars acquisition pattern (R~1.8) with a 3D total variation constraint. The long reconstruction time of these CS methods makes them unwieldy to use, especially the patch based collaborative filtering technique. In addition, the effect of CS techniques on the quantification of percentage of scar/fibrosis is not known. We sought to develop a practical compressed sensing method for imaging the LA at high acceleration factors. In order to develop a clinically viable method with short reconstruction time, a Split Bregman (SB) reconstruction method with 3D total variation (TV) constraints was developed and implemented. The method was tested on 8 atrial fibrillation patients (4 pre-ablation and 4 post-ablation datasets). Blur metric, normalized mean squared error and peak signal to noise ratio were used as metrics to analyze the quality of the reconstructed images, Quantification of the extent of LGE was performed on the undersampled images and compared with the fully sampled images. Quantification of scar from post-ablation datasets and quantification of fibrosis from pre-ablation datasets showed that acceleration factors up to R~3.5 gave good 3D LGE images of the LA wall, using a 3D TV constraint and constrained SB methods. This corresponds to reducing the scan time by half, compared to currently used GRAPPA methods. Reconstruction of 3D LGE images using the SB method was over 20 times faster than standard gradient descent methods.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4946994 | PMC |
http://dx.doi.org/10.1016/j.mri.2016.03.002 | DOI Listing |
Pain Manag
September 2025
Serviço de Reabilitação de Adultos 3, Centro de Medicina de Reabilitação de Alcoitão, Alcabideche, Portugal.
Pudendal neuropathy is a cause of pelvic pain, specifically pudendal neuralgia. The pudendal nerve is related to sensory, motor, and autonomic functions. We present the case of a 41-year-old man who suffered from chronic pelvic pain.
View Article and Find Full Text PDFFood Res Int
November 2025
Institute of Food Research, National Agriculture and Food Research Organization (NARO), 2-1-12 Kannondai, Tsukuba, Ibaraki 305-8642, Japan.
Accurately assessing saltiness perception in solid foods is essential for the development of low-sodium foods that maintain saltiness despite possessing a lower sodium content. This study aimed to develop a practical system for evaluating human-perceived saltiness during oral processing, particularly when food was initially placed on the tongue. As a basis for system design, sensory evaluations demonstrated that higher local salt concentrations (inhomogeneous distribution) on the tongue significantly enhanced perceived saltiness intensity compared to a homogeneous distribution, despite equal total salt content.
View Article and Find Full Text PDFMacromol Rapid Commun
September 2025
School of Materials and Chemistry, Anhui Agricultural University, Hefei, Anhui, China.
At present, flexible sensors are a hot spot in research and experimental development, but the research on flexible sensors that can be used for human motion monitoring still needs to be deepened. In this work, the green material cellulose acetate (CA) was used as the matrix material, the film was made by electrospinning, crushed by a cell grinder and sodium alginate (SA) was added to promote the uniform dispersion of nanofibers in water, and then methyltrimethoxysilane (MTMS) and MXene nanosheet dispersion were added to make it hydrophobic and good conductivity, and the aerogel precursor solution was prepared, and then the CA/SA/MTMS/MXene aerogel with directional holes was prepared by directional freeze-drying. As a flexible sensor material, it can be used for human wear, monitoring the electrical signals generated by the movement of human joints and other parts, and can still maintain a current of about 0.
View Article and Find Full Text PDFACS Appl Mater Interfaces
September 2025
Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand.
Strain sensors have received considerable attention in personal healthcare due to their ability to monitor real-time human movement. However, the lack of chemical sensing capabilities in existing strain sensors limits their utility for continuous biometric monitoring. Although the development of dual wearable sensors capable of simultaneously monitoring human motion and biometric data presents significant challenges, the ability to fabricate these sensors with geometries tailored to individual users is highly desirable.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
September 2025
Robotics Institute, Ningbo University of Technology, Ningbo, China.
Surface electromyography (sEMG) holds great potential in walking function evaluation. Compressed sensing (CS) leverages the sparsity of signals to decrease the number of samples required. In this study, a sEMG CS algorithm for spinal cord injury (SCI) patients based on regularized orthogonal matching pursuit (ROMP) was introduced.
View Article and Find Full Text PDF