A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Aptamer selection by direct microfluidic recovery and surface plasmon resonance evaluation. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A surface plasmon resonance (SPR)-based SELEX approach has been used to raise RNA aptamers against a structured RNA, derived from XBP1 pre-mRNA, that folds as two contiguous hairpins. Thanks to the design of the internal microfluidic cartridge of the instrument, the selection was performed during the dissociation phase of the SPR analysis by recovering the aptamer candidates directly from the target immobilized onto the sensor chip surface. The evaluation of the pools was performed by SPR, simultaneously, during the association phase, each time the amplified and transcribed candidates were injected over the immobilized target. SPR coupled with SELEX from the first to the last round allowed identifying RNA aptamers that formed highly stable loop-loop complexes (KD equal to 8nM) with the hairpin located on the 5' side of the target. High throughput sequencing of two key rounds confirmed the evolution observed by SPR and also revealed the selection of hairpins displaying a loop not fully complementary to the loop of its target. These candidates were selected mainly because they bound 79 times faster to the target than those having a complementary loop. SELEX coupled with SPR is expected to speed up the selection process because selection and evaluation are performed simultaneously.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2016.02.003DOI Listing

Publication Analysis

Top Keywords

surface plasmon
8
plasmon resonance
8
rna aptamers
8
complementary loop
8
spr
5
target
5
aptamer selection
4
selection direct
4
direct microfluidic
4
microfluidic recovery
4

Similar Publications