Article Abstract

X-ray microtomography (micro-CT), one of the most resourceful instruments for high resolution 3D analysis, can provide qualitative and quantitative accurate structural and compositional information for a broad range of materials. Yet its contribution to the field of biopolymeric materials science is often limited by low imaging contrast due to scarce X-ray attenuation features, particularly for sponges and foam-like structures. This limitation can be overcome to some extent by adjusting the working parameters of micro-CT equipment. However, such approach also facilitates noise and artefacts, and solving the signal-to-noise trade-off has been always problematic. Searching for alternatives turns one's attention towards the improvement of X-ray attenuation features. While several studies report the use of contrast agents for biological materials, studies to integrate multiple micro-CT approaches for biopolymers were not conducted so far. This method paper is thus aimed to serve as a platform for micro-CT analysis of low X-ray absorptive polymers. Here, several contrast enhancing artifices were developed and trialled on gelatin and poly(vinyl alcohol) biopolymer composites (GP). Accordingly, GP were modified with iodine, barium, silver-based chemicals and hexa(methyl disilazane) by two different methods, i.e. addition of high atomic number chemicals during materials synthesis and post-synthesis staining, respectively. Consequently, cross-sectional scanning electron microscopy emerged as complementary characterization, aimed to confirm the reproducibility of samples morphological features. The most versatile methods were barium chloride additive incorporation and iodine staining coupled with hexa(methyl disilazane) chemical drying. Both methods significantly improved the X-ray absorbance of our polymeric samples, providing better contrast of micro-CT tomograms.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09205063.2016.1152856DOI Listing

Publication Analysis

Top Keywords

micro-ct analysis
8
analysis low
8
x-ray attenuation
8
attenuation features
8
hexamethyl disilazane
8
micro-ct
6
x-ray
5
enhanced x-ray
4
x-ray absorption
4
absorption micro-ct
4

Similar Publications

Synthesis, preclinical evaluation and clinical application of a novel heterodimeric tracer Ga-pentixafor-c(RGDfK) for PET-CT imaging.

Eur J Nucl Med Mol Imaging

September 2025

Department of PET-CT/MRI, NHC Key Laboratory of Molecular Probe and Targeted Theranostics, Harbin Medical University Cancer Hospital, Harbin, 150081, Heilongjiang, China.

Objective: CXCR4 and integrin αβ play important roles in tumor biology and are highly expressed in multiple types of tumors. This study aimed to synthesize, preclinically evaluate, and clinically validate a novel dual-targeted PET imaging probe Ga-pentixafor-c(RGDfK) for its potential in imaging tumors.

Methods: The effects of Ga-pentixafor-c(RGDfK) on cell viability, targeting specificity, and affinity were assessed in the U87MG cells.

View Article and Find Full Text PDF

Purpose: Modifying interference screw composition may ensure better osteoconductive properties in order to reduce tunnel enlargement after anterior cruciate ligament (ACL) reconstruction. The primary and secondary purposes were to evaluate tunnel and screw volume changes in poly-L-lactide acid (PLLA) and poly-D-lactic acid + hydroxyapatite + β-tricalcium phosphate (PLDLA+) screws. The tertiary purpose was to compare patient reported- and functional outcomes between PLLA and PLDLA+ group.

View Article and Find Full Text PDF

: Postmenopausal conditions can lead to metabolic disorders such as obesity and steatosis. (PT), a prominent traditional Chinese medicine, exerts potential therapeutic effects against hepatic injury. Nevertheless, the extent to which PT ameliorates liver damage resulting from estrogen deficiency, along with the associated mechanisms, remains poorly understood.

View Article and Find Full Text PDF

This study investigated the anti-periodontitis effects of MENP (mixed extracts from multiple natural plants with a certain percentage). Lipopolysaccharide from (LPS-PG) was used to stimulate Raw 264.7 and human gingival fibroblast-1 cells.

View Article and Find Full Text PDF

Bone infections caused by and are serious complications in orthopedic surgery. These infections commonly occur in joint replacements, fracture management, and bone grafting procedures. Rapid and accurate pathogen-specific diagnostic methods are urgently needed to support early clinical decisions.

View Article and Find Full Text PDF