Article Abstract

Improper femoral component size remains a source of multiple postoperative complications following total knee arthroplasty (TKA). However, the use of a flexible intramedullary (IM) rod may help optimize femoral component size and therefore improve outcomes. The purpose of this study was to assess (1) patient-reported functional outcomes, (2) overall quality of life, and (3) changes in implant sizing associated with total knee arthroplasties performed with a flexible IM rod compared to a conventional, rigid rod. We reviewed 277 patients who had surgery using the rigid rod and 364 using the flexible rod to determine the tendency of each rod for selecting particular component sizes. Additionally, 100 patients were prospectively randomized (1:1) to the flexible or the conventional rigid IM rod cohorts. Outcomes were assessed using Knee Society scores (KSSs), SF-36 physical scores, and SF-36 mental scores preoperatively and at 6 weeks, 3 months, 1 year, and 2 years postoperatively. The retrospective arm of the study showed that the flexible IM rod cohort tends to have smaller component sizes than their conventional counterparts. In the prospective phase of the study, the increase in clinical KSSs from preoperative levels was better in the flexible rod cohort (160% vs. 143% increases, respectively). The functional KSSs had slightly higher increases in the flexible rod cohort from their preoperative levels (68% vs. 62% increases, respectively). With both clinical and functional KSSs, the flexible rod cohort had a higher score than the rigid rod cohort at all follow-up points. There was better postoperative range of motion (ROM) in the flexible rod cohort (28% vs. 22% increases, respectively). The SF-36 physical scores were slightly different, with the flexible IM rod cohort having a more marked improvement in scores (64% vs. 46% increases, respectively). The SF-36 mental score had a slightly better improvement at latest follow-up in the flexible IM rod cohort (12% vs. 6% increases, respectively). Those patients who underwent TKA using a flexible IM rod had better improvements in their patient-reported outcomes and decreased risk of oversizing the femoral component. The use of such a rod is not detrimental to outcomes and may have a positive impact on outcomes. Future studies should focus on alignment and long-term outcomes associated with the use of a flexible rod.

Download full-text PDF

Source
http://dx.doi.org/10.1615/jlongtermeffmedimplants.2015013275DOI Listing

Publication Analysis

Top Keywords

flexible rod
44
rod cohort
32
rod
19
rigid rod
16
flexible
14
total knee
12
femoral component
12
flexible intramedullary
8
intramedullary rod
8
knee arthroplasty
8

Similar Publications

Collective behavior of "flexicles".

Proc Natl Acad Sci U S A

September 2025

Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109.

In recent years the functionality of synthetic active microparticles has edged even closer to that of their biological counterparts. However, we still lack the understanding needed to recreate at the microscale key features of autonomous behavior exhibited by microorganisms or swarms of macroscopic robots. In this study, we propose a model for a three-dimensional deformable cellular composite particle consisting of self-propelled rod-shaped colloids confined within a flexible vesicle-representing a superstructure we call a "flexicle" that couples particle deformation to the internal dynamics of the internal active components.

View Article and Find Full Text PDF

Styles are invasive medical devices that are visible on images and are used in several medical specialties, including cardiology, neurology, orthopaedics, anaesthesia, oto-rhino-laryngology (ENT), and dentistry. With their thin and flexible design, they allow for the optimal positioning and precise guidance of medical devices such as nerve stimulation, defibrillation, electrode positioning, and catheter insertion. Generally, they are made of stainless steel, offering a combination of rigidity and flexibility.

View Article and Find Full Text PDF

Objective: Multipoint pelvic fixation with multirod constructs is increasingly used for long-segment deformity constructs to reduce rates of distal failure. However, more robust distal fixation may negatively impact proximal junction biomechanics, and this potential relationship has not been extensively studied.

Methods: Standard nondestructive flexibility tests (7.

View Article and Find Full Text PDF

Single Mitochondrion Morphology-Function Relationship Analysis Using Fluorescent Probes and Artificial Intelligence.

Adv Sci (Weinh)

August 2025

State Key Laboratory of Flexible Electronics (LoFE) & Institute of Flexible Electronics (IFE), Northwestern Polytechnical University, Xi'an, 710072, China.

The ability to decode the relationship between mitochondrial morphology and function at the level of individual organelles is central to understanding cellular responses to stress, such as hypoxia. Herein, a comprehensive strategy is presented that integrates tailored fluorescent probes with artificial intelligence (AI) for single mitochondrion analysis. Focus is on three interrelated biomarkers, reactive oxygen species (ROS), viscosity, and mitochondrial membrane potential (MMP), that together form a pathophysiological axis indicative of mitochondrial state under hypoxic stress.

View Article and Find Full Text PDF

The concept of framework isomers by network topology analysis is illustrated by a new rod-MOF isomer of In and the tritopic linker 4,4',4''-(benzene-1,3,5-triyl-tris(oxy))tribenzoic acid (Hbttb), CTH-41, with a unique 3- and 4-connected net different from 437-MOF. CTH-41 shows affinity for SF with a Langmuir area of 1587 m g while the new Zr dot-MOF with the same linker [Zr(bttb)(O)(OH)] CTH-42, forms the 3-, 12-connected llj-net based on a different conformation of the flexible bttb linker.

View Article and Find Full Text PDF