A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Highly sensitive and selective detection of human carboxylesterase 1 activity by liquid chromatography with fluorescence detection. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Human carboxylesterases 1 (hCE1), one of the most important human drug metabolizing enzymes, catalyzes the hydrolysis of a large number of structurally diverse of endogenous and exogenous substrates. However, a practical, reliable and sensitive method for the precise measurement of hCE1 activities in complex biological samples has been rarely reported. In this study, a liquid chromatography-fluorescence detection (LC-FD) based method was developed for highly selective and sensitive measurement of hCE1 activities in human tissue and cell preparations. This method was based on the fluorimetric detection of HMBT, the hydrolyzed product of BMBT which was a newly developed specific probe substrate for hCE1. The developed LC-FD method was fully validated in terms of specificity, sensitivity, linearity, precision, recovery and stability. With the help of LC separation, most polar endogenous compounds in biological samples could be eluted in the column dead time, which is very beneficial for accurate determination of hCE1 activities in complex biological samples. The lower limit of quantification for HMBT (product of hCE1) of this LC-FD based method was as low as 20nM, which was quite lower than other reported methods. The method also exhibited good precision, both intra- and inter- assay variances were both lower than 2.5%. Furthermore, the newly developed method was successfully applied to measure hCE1 activity in human liver preparations from individual donors (n=12), as well as in homogenates from eleven different human cell lines. All these findings combined with this practical method are very helpful for the deep understanding of the expression and function of hCE1 in human biological samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2015.11.046DOI Listing

Publication Analysis

Top Keywords

biological samples
16
hce1 activities
12
detection human
8
hce1
8
hce1 human
8
method
8
measurement hce1
8
activities complex
8
complex biological
8
lc-fd based
8

Similar Publications