98%
921
2 minutes
20
In this Letter, we present a digital micromirror device (DMD)-based ultrafast beam shaper, i.e., DUBS. To our knowledge, the DUBS is the first binary laser beam shaper that can generate high-resolution (1140×912 pixels) arbitrary beam modes for femtosecond lasers at a rate of 4.2 kHz; the resolution and pattern rate are limited by the DMD. In the DUBS, the spectrum of the input pulsed laser is first angularly dispersed by a transmission grating and subsequently imaged to a DMD with beam modulation patterns; the transmission grating and a high-reflectivity mirror together compensate the angular dispersion introduced by the DMD. The mode of the output beam is monitored by a CCD camera. In the experiments, the DUBS is programmed to generate four different beam modes, including an Airy beam, Bessel beam, Laguerre-Gaussian (LG) beam, and a custom-designed "peace-dove" beam via the principle of binary holography. To verify the high shaping rate, the Airy beam and LG beam are generated alternately at 4.2 kHz, i.e., the maximum pattern rate of our DMD. The overall efficiency of the DUBS is measured to be 4.7%. With the high-speed and high-resolution beam-shaping capability, the DUBS may find important applications in nonlinear microscopy, optical manipulation, and microscale/nanoscale laser machining, etc.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.40.004875 | DOI Listing |
J Neurooncol
September 2025
Department of Radiation Oncology, Massachusetts General Hospital, Boston, USA.
Purpose: Cranial irradiation is associated with health-related quality of life (HRQoL) deficits in childhood cancer survivors. We investigated the relationship between radiation dose to brain substructures and HRQoL in children with brain tumors treated with proton beam therapy (PBT).
Methods: Data were obtained from children in the Pediatric Proton/Photon Consortium Registry who received PBT for primary brain tumors between 2015 and 2021.
Strahlenther Onkol
September 2025
Department of Radiation Oncology, University Hospital of Münster, Münster, Germany.
The growing use of reduced-dose radiotherapy in patients with primary cutaneous lymphoma is a promising development. Nevertheless, the absence of controlled clinical trials to ascertain standardized doses for each specific type constitutes a significant impediment to the advancement of this field. This expert opinion strongly advocates for advancements in radiation oncology practice that address the unique complexities of primary cutaneous lymphoma.
View Article and Find Full Text PDFRev Sci Instrum
September 2025
SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.
We report on the development of a robust microfluidic nozzle capable of generating replenishing liquid sheet targets with sub-micron thickness at up to kHz repetition rates, a λ/20 surface flatness over areas of at least 100 μm2, and in-vacuum dimensions of 6 × 1.5 mm2. The platform was evaluated for stability under hundreds of 4.
View Article and Find Full Text PDFPhotoacoustics
October 2025
Hubei Key Laboratory of Intelligent Wireless Communications, Hubei Engineering Research Center of Intelligent IOT technology, College of Electronics and Information Engineering, South-Central Minzu University, Wuhan 430074, China.
A novel gourd-type photoacoustic cell (GTPAC) has been developed, featuring a highly reflective, polished gold film-coated inner wall that minimizes optical loss and maximizes light utilization efficiency. GTPAC integrates two coupled spherical chambers with a radius ratio 2:3, which is close to the golden ratio. Its unique Gaussian curvature distribution enables multi-directional, disordered light beam reflection without complex optical alignment.
View Article and Find Full Text PDFCureus
August 2025
Department of Oral and Maxillofacial Surgery, University College of Medicine and Dentistry, The University of Lahore, Lahore, PAK.
Background And Aim: The incisive (nasopalatine) canal is an important anatomical structure of the anterior maxilla. It holds significance for surgeries and implant placement in the central incisor region. The size, shape, and relation with surrounding bones may vary by age, gender, and ethnicity.
View Article and Find Full Text PDF