A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

VariantMetaCaller: automated fusion of variant calling pipelines for quantitative, precision-based filtering. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The low concordance between different variant calling methods still poses a challenge for the wide-spread application of next-generation sequencing in research and clinical practice. A wide range of variant annotations can be used for filtering call sets in order to improve the precision of the variant calls, but the choice of the appropriate filtering thresholds is not straightforward. Variant quality score recalibration provides an alternative solution to hard filtering, but it requires large-scale, genomic data.

Results: We evaluated germline variant calling pipelines based on BWA and Bowtie 2 aligners in combination with GATK UnifiedGenotyper, GATK HaplotypeCaller, FreeBayes and SAMtools variant callers, using simulated and real benchmark sequencing data (NA12878 with Illumina Platinum Genomes). We argue that these pipelines are not merely discordant, but they extract complementary useful information. We introduce VariantMetaCaller to test the hypothesis that the automated fusion of measurement related information allows better performance than the recommended hard-filtering settings or recalibration and the fusion of the individual call sets without using annotations. VariantMetaCaller uses Support Vector Machines to combine multiple information sources generated by variant calling pipelines and estimates probabilities of variants. This novel method had significantly higher sensitivity and precision than the individual variant callers in all target region sizes, ranging from a few hundred kilobases to whole exomes. We also demonstrated that VariantMetaCaller supports a quantitative, precision based filtering of variants under wider conditions. Specifically, the computed probabilities of the variants can be used to order the variants, and for a given threshold, probabilities can be used to estimate precision. Precision then can be directly translated to the number of true called variants, or equivalently, to the number of false calls, which allows finding problem-specific balance between sensitivity and precision.

Conclusions: VariantMetaCaller can be applied to small target regions and whole exomes as well, and it can be used in cases of organisms for which highly accurate variant call sets are not yet available, therefore it can be a viable alternative to hard filtering in cases where variant quality score recalibration cannot be used. VariantMetaCaller is freely available at http://bioinformatics.mit.bme.hu/VariantMetaCaller .

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4625715PMC
http://dx.doi.org/10.1186/s12864-015-2050-yDOI Listing

Publication Analysis

Top Keywords

variant calling
16
calling pipelines
12
call sets
12
variant
11
automated fusion
8
variant quality
8
quality score
8
score recalibration
8
hard filtering
8
variant callers
8

Similar Publications