We present a technique to improve signal strength, and therefore sensitivity in distributed temperature and strain sensing (DTSS) using Frequency domain Rayleigh scatter. A simple UV exposure of a hydrogen loaded standard SMF-28 fibre core is shown to enhance the Rayleigh back-scattered light dramatically by ten-fold, independent of the presence of a Bragg grating, and is therefore created by the UV exposure alone. This increase in Rayleigh back-scatter allows an order-of-magnitude increase in temperature and strain resolution for DTSS compared to un-exposed SMF-28 fibre used as a sensing element. This enhancement in sensitivity is effective for cm range or more sensor gauge length, below which is the theoretical cross-correlation limit. The detection of a 20 mK temperature rise with a spatial resolution of 2 cm is demonstrated. This gain in sensitivity for SMF-28 is compared with a high Ge doped photosensitive fibre with a characteristically high NA. For the latter, the UV enhancement is also present although of lower amplitude, and enables an even lower noise level for sensing, due to the fibre's intrinsically higher Rayleigh scatter signal.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4650692 | PMC |
http://dx.doi.org/10.1038/srep11177 | DOI Listing |
J Biomed Opt
December 2025
University of Toronto, Department of Medical Biophysics, Temerty Faculty of Medicine, Toronto, Ontario, Canada.
Significance: Tumor tissues exhibit contrast with healthy tissue in circular degree of polarization (DOP) images via higher magnitude circular DOP values and increased helicity-flipping. This phenomenon may enable polarimetric tumor detection and surgical/procedural guidance applications.
Aim: Depolarization metrics have been shown to exhibit differential responses to healthy and cancer tissue, whereby tumor tissues tend to induce less depolarization; however, the understanding of this depolarization-based contrast remains limited.
Appl Phys B
September 2025
Department of Mechanical Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands.
Unlabelled: In the framework of the Argon Power Cycle, millisecond-pulsed hydrogen gas injections into a high-pressure, room temperature nitrogen or argon ambient are investigated. Instantaneous Rayleigh scattering is used to quantify the hydrogen mole fraction in the ensuing jets. A readily available HDEV injector with a straight 0.
View Article and Find Full Text PDFLangmuir
September 2025
Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection (Guangxi Normal University), Ministry of Education, Guilin 541004, China.
A new nanosurface molecularly imprinted polyacrylamide nanoprobe (FeO@MIP) for pH sensing was prepared by using FeO magnetic nanoparticles as a substrate, rhodamine B (RhB) as a template and sensing molecule, acrylamide (AM) as a functional monomer, and ethylene glycol dimethacrylate (EGDMA) as a cross-linker. The nanoprobe was characterized by scanning electron microscopy (SEM), hysteresis loop, Fourier transform infrared spectroscopy (FT-IR), and resonance Rayleigh scattering (RRS) spectroscopy. FeO@MIP exhibited a strong RRS peak at 375 nm, and the sensing molecule RhB as the acceptor was enhanced with increasing pH in the pH range of 2.
View Article and Find Full Text PDFOpt Lett
September 2025
The optical spectrum analyzer based on stimulated Brillouin scattering (SBS-OSA) has important application potential in the field of optical communication and optical sensing due to its sub-picometer resolution. However, the sensitivity is limited by amplified Brillouin scattering (ABS) noise and Rayleigh backscattering (RB) noise. Therefore, the source and characteristics of noise in SBS-OSA are analyzed, and a noise suppression method based on polarization filtering is proposed in this paper.
View Article and Find Full Text PDFLarge-scale strain (i.e., large strain in wide-range optical fiber) distorts distance referencing in spectrum-based optical frequency-domain reflectometry (OFDR), resulting in severe position segment mismatches and degraded accuracy.