98%
921
2 minutes
20
The primary aim of this study was to compare rating of perceived exertion (RPE) values measuring repetitions in reserve (RIR) at particular intensities of 1 repetition maximum (RM) in experienced (ES) and novice squatters (NS). Furthermore, this investigation compared average velocity between ES and NS at the same intensities. Twenty-nine individuals (24.0 ± 3.4 years) performed a 1RM squat followed by a single repetition with loads corresponding to 60, 75, and 90% of 1RM and an 8-repetition set at 70% 1RM. Average velocity was recorded at 60, 75, and 90% 1RM and on the first and last repetitions of the 8-repetition set. Subjects reported an RPE value that corresponded to an RIR value (RPE-10 = 0-RIR, RPE-9 = 1-RIR, and so forth). Subjects were assigned to one of the 2 groups: (a) ES (n = 15, training age: 5.2 ± 3.5 years) and (b) NS (n = 14, training age: 0.4 ± 0.6 years). The mean of the average velocities for ES was slower (p ≤ 0.05) than NS at 100% and 90% 1RM. However, there were no differences (p > 0.05) between groups at 60, 75%, or for the first and eighth repetitions at 70% 1RM. In addition, ES recorded greater RPE at 1RM than NS (p = 0.023). In ES, there was a strong inverse relationship between average velocity and RPE at all percentages (r = -0.88, p < 0.001), and a strong inverse correlation in NS between average velocity and RPE at all intensities (r = -0.77, p = 0.001). Our findings demonstrate an inverse relationship between average velocity and RPE/RIR. Experienced squatter group exhibited slower average velocity and higher RPE at 1RM than NS, signaling greater efficiency at high intensities. The RIR-based RPE scale is a practical method to regulate daily training load and provide feedback during a 1RM test.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1519/JSC.0000000000001049 | DOI Listing |
Ultrasonics
August 2025
College of Biomedical Engineering, Fudan University, Shanghai 200438, China; State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai 200438, China; Poda Medical Technology Co., Ltd., Shanghai 200433, China. Electronic address:
Transcranial ultrasound localization microscopy (t-ULM) is faced with challenges posed by the skull, including acoustic attenuation and phase aberrations. There is a significant request for an efficient aberration correction method achieving a great balance between computational complexity and accuracy. In this study, the ray theory is first applied to in-vivo transcranial imaging to calculate the traveltime table in the inhomogeneous medium model of the imaging region.
View Article and Find Full Text PDFReprod Domest Anim
September 2025
Department of Biological Sciences, State University of Santa Cruz (UESC), Ilhéus, Bahia, Brazil.
Characterising body and reproductive morphometry and their association with epididymal sperm quality can contribute to the conservation of sambar deer (Rusa unicolor). Five adult males maintained in captivity at the Getúlio Vargas Zoobotanical Park (Salvador, BA, Brazil) were captured, anaesthetised, and subjected to bilateral orchiectomy as part of a population-control strategy. Body measurements included head circumference, thoracic diameter, total length, withers height, and body weight.
View Article and Find Full Text PDFJACC Case Rep
September 2025
Atrium Health Navicent, Macon, Georgia, USA.
Background: Pulmonary hypertension (PH) is frequently underdiagnosed due to limitations of transthoracic echocardiography, particularly when tricuspid regurgitant velocity (TRV) is unmeasurable. CorVista PH (point-of-care test for pulmonary hypertension [POC-PH]) is a novel, Food and Drug Administration-cleared point-of-care diagnostic with 82% sensitivity and 92% specificity for identifying mean pulmonary artery pressure elevation.
Summary: We present a patient who underwent multiple transthoracic echocardiograms negative for PH.
J Appl Physiol (1985)
September 2025
Cardiovascular Research Laboratory, Spaulding Hospital Cambridge, Cambridge, MA.
Assessment of sympathetic transduction into its effects on the cardiovascular system is of great interest in human research. Analysis of sympathetic transduction has been divided into neurovascular and neurohemodynamic, highlighting the sympathetic effect on either regional vascular or systemic pressure responses. This study investigates whether indices of neurovascular transduction are reflected in parallel neurohemodynamic transduction during normoxia and hypoxia, with and without accounting for the confounds of prevailing tachypnea and tachycardia.
View Article and Find Full Text PDFUltrasonics
September 2025
Nantes Université, Ecole Centrale Nantes, CNRS, GeM, UMR 6183, F-44000 Nantes, France.
This study investigates the sensitivity of ultrasonic phase velocity and attenuation statistics to grain size distribution types, specifically monomodal and bimodal, in cubic finite-sized polycrystals with identical overall arithmetic or volumetric grain size statistics. A large ensemble of synthetic polycrystalline microstructures was generated, and their ultrasonic responses were computed using a modified spectral function method. The latter enables estimation of both effective phase velocities and attenuation coefficients while rigorously accounting for finite specimen dimensions and statistical variabilities across different samples.
View Article and Find Full Text PDF