Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: In order to improve the clinical treatment level of urinary system injury, it is necessary to build up an animal model of urinary system wound, which is not only analogous to real clinical practice, but also simple and practical.

Methods: We have developed the third generation of firearm fragment wound generator based on the first and the second producer. The best explosive charge of the blank cartridge was selected by gradient powder loading experiments. The firearm fragment injuries were made to the bulbous urethra of 10 New Zealand male rabbits. One week preoperatively and 2, 4 and 8 weeks postoperatively, all the animals underwent urethroscopy and urethrography. At 2, 4 and 8 weeks postoperatively, two animals were randomly selected and killed, and the urethra was cut off for pathological examination.

Results: The shooting distance of the third generation of firearm fragment wound generator is 2 cm. The best explosive charge of the blank cartridge is 1 g of nitrocotton. All rabbits survived the procedures and stayed alive until they were killed. Injuries were limited to bulbous urethra and distal urethra. Round damaged areas, 1-1.5 cm in length, on the ventral wall were observed. Ureteroscopy results showed that canal diameter gradually shrank by over 50% in 9 rabbits. The rate of success was 90%. Urethrography result noted that a 1-1.3 cm stricture was formed at the bulbous urethra. Histology results of injured stricture urethra showed that fibrous connective tissue hyperplasia and hyaline degeneration caused further stricture in the canal.

Conclusions: The third generation of firearm fragment wound generator imitates the bullet firing process and is more accurate and repeatable. The corresponding rabbit model of traumatic complex urethral stricture simulates the real complex clinical conditions. This animal model provides a standardized platform for clinical researches on treating traumatic injuries to the urinary system.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4834010PMC
http://dx.doi.org/10.4103/0366-6999.154299DOI Listing

Publication Analysis

Top Keywords

urinary system
16
firearm fragment
16
third generation
12
generation firearm
12
fragment wound
12
wound generator
12
bulbous urethra
12
model urinary
8
system injury
8
animal model
8

Similar Publications

Background: Healthcare-associated infections (HCAIs) pose a serious threat to healthcare systems. Accurately determining the incidence of HCAIs is crucial for planning and implementing efficient interventions, as they are associated with a wide range of challenges. The objective of this study was to assess and update the incidence rates of HCAIs in Iran in 2023, using data from the Iranian Nosocomial Infection Surveillance (INIS) system, a nationwide hospital-based surveillance program.

View Article and Find Full Text PDF

Drug-associated postpartum hemorrhage: a comprehensive disproportionality analysis based on the FAERS database.

Naunyn Schmiedebergs Arch Pharmacol

September 2025

Department of Pharmacy, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Maternity and Child Health Hospital, Fujian Medical University, #18 Daoshan Road, Fuzhou, Fujian, 350001, China.

Postpartum hemorrhage (PPH) is a life-threatening obstetric complication. We aimed to identify the drugs that associated with PPH based on the FDA Adverse Event Reporting System (FAERS) data, providing scientific evidence for targeted prevention of drug-related PPH risk factors. Data from 2004Q1 to 2025Q1 were extracted from FAERS, and disproportionality analysis was performed to identify potential drug signals.

View Article and Find Full Text PDF

Introduction: Nicotine pouches (NPs) are an emerging nicotine delivery system. Understanding nicotine and toxicant exposure among NP users compared with users of other tobacco products and non-users is critical for informing public health strategies.

Methods: Data (n = 4527) were drawn from the Population Assessment of Tobacco and Health Study Wave 7 (2022-2023).

View Article and Find Full Text PDF

A retrospective cohort study compared generative artificial intelligence (GenAI) vs. infection control expert for catheter-associated urinary tract infection (CAUTI) detection. Sensitivity was 95.

View Article and Find Full Text PDF

The goal was to develop a pragmatic classification system for conditions associated with chronic pelvic pain (CPP), aiming to enhance diagnosis, management, education, and research of CPP. An international, multidisciplinary panel participated in a modified RAND/UCLA Delphi consensus. This panel included healthcare professionals, medical society representatives, experts, individuals with lived experience of pain, advocacy groups, researchers, educators, and journal editors.

View Article and Find Full Text PDF