Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The fast development of sensitive molecular diagnostic tools is currently paving the way for a personalized medicine. A new class of ultrasensitive magnetic resonance imaging (MRI) T₂-contrast agents based on magnetosomes, magnetite nanocrystals biomineralized by magnetotactic bacteria, is proposed here. The contrast agents can be injected into the blood circulation and detected in the picomolar range. Purified magnetosomes are water-dispersible and stable within physiological conditions and exhibit at 17.2 T a transverse relaxivity r₂ four times higher than commercial ferumoxide. The subsequent gain in sensitivity by T₂(*) -weighted imaging at 17.2 T of the mouse brain vasculature is evidenced in vivo after tail vein injection of magnetosomes representing a low dose of iron (20 μmoliron kg(-1)), whereas no such phenomenon with the same dose of ferumoxide is observed. Preclinical studies of human pathologies in animal models will benefit from the combination of high magnetic field MRI with sensitive, low dose, easy-to-produce biocompatible contrast agents derived from bacterial magnetosomes.

Download full-text PDF

Source
http://dx.doi.org/10.1002/adhm.201400756DOI Listing

Publication Analysis

Top Keywords

imaging 172
8
contrast agents
8
low dose
8
magnetosomes
5
magnetosomes biogenic
4
biogenic magnetic
4
magnetic nanomaterials
4
nanomaterials brain
4
brain molecular
4
molecular imaging
4

Similar Publications

Background: Bone marrow (BM) lesion differentiation remains challenging, and quantitative magnetic resonance imaging (MRI) may enhance accuracy over conventional methods. We evaluated the diagnostic value and inter-reader reliability of Dixon-based signal drop (%drop) and fat fraction percentage (%fat) as adjuncts to existing protocols.

Materials And Methods: In this prospective two-center study, 172 patients with BM signal abnormalities underwent standardized 1.

View Article and Find Full Text PDF

Objective: To investigate the characteristics of brain structures in patients with noise-induced hearing loss (NIHL) using source-based morphometry (SBM) and to evaluate the correlation between abnormal brain regions and clinical data.

Methods: High-resolution 3D T1 structural images were acquired from 81 patients with NIHL and 74 age- and education level-matched healthy controls (HCs). The clinical data of all subjects were collected, including noise exposure time, monaural hearing threshold weighted values (MTWVs), Mini-Mental State Examination (MMSE), and Hamilton Anxiety Scale (HAMA) scores.

View Article and Find Full Text PDF

Geometric changes in the sigmoid sinus diverticulum (SSD) can alter its hemodynamic - a primary factor contributing to pulsatile tinnitus (PT). However, not all SSD cases lead to clinical PT symptoms. This study aims to investigate the influence of the diameter of the diverticulum (EDD) on the hemodynamics of the sigmoid sinus in PT.

View Article and Find Full Text PDF

Myocardial Perfusion Imaging and Revascularization Predict Long-term All-cause Mortality in Patients with Suspected CAD.

Acad Radiol

September 2025

Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan (J.Y.H., C.L.K., K.L.C.); College of Medicine, National Taiwan University, Taipei, Taiwan (J.Y.H., C.K.H., K.L.C., Y.W.W.); Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan (C.K

Rationale And Objectives: The prognostic implications of myocardial perfusion imaging (MPI) are imperative to provide proper management of coronary artery disease (CAD). This study aimed to quantify the long-term prognostic value of MPI under routine clinical conditions.

Materials And Methods: This single-center retrospective cohort study evaluated all-cause mortality and cause-specific survival according to MPI findings in patients with suspected or known CAD who underwent diagnostic evaluation or assessment of myocardial ischemia and viability in a tertiary referral cardiovascular center.

View Article and Find Full Text PDF

This study explored the application value of iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL-IQ) technology in the early diagnosis of ageing osteoporosis (OP). 172 participants were enrolled and underwent magnetic resonance imaging (MRI) examinations on a 3.0T scanner.

View Article and Find Full Text PDF