Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac503931gDOI Listing

Publication Analysis

Top Keywords

microfluidic-based sampling
12
sampling procedure
12
hct levels
12
blood
10
dried blood
8
blood spot
8
hct
8
dbs sample
8
sample analysis
8
blood volume
8

Similar Publications

In this paper, we describe how 3D printing can be used to fabricate a microfluidic-based transwell cell culture system with robust fluidic connections for long-term cell culture and recirculating flow. This approach consists of an electrospun collagen scaffold sandwiched between two laser-cut Teflon membranes that match the fluidic design. Madin-Darby canine kidney (MDCK) cells were cultured on the collagen scaffold to create an epithelial cell monolayer.

View Article and Find Full Text PDF

Microfluidic-assisted analysis of extracellular vesicles for advanced biomedical applications.

Chem Commun (Camb)

August 2025

Key Laboratory of Hainan Trauma and Disaster Rescue, The First Affiliated Hospital of Hainan Medical University, School of Pharmacy, The Second Affiliated Hospital of Hainan Medical University, Hainan Medical University, Haikou 571199, China.

Extracellular vesicles are lipid bilayer-enclosed nanoparticles that play a crucial role in intercellular communication by transporting bioactive molecules across cells, tissues, and even organisms. Although certain aspects of EV biogenesis, function, and metabolic pathways are yet to be fully elucidated, their distinctive features such as cargo protection, structural stability, and the capacity to cross biological barriers render them highly promising for medical applications, especially as novel biomarkers for disease diagnosis. However, the ultrasmall size and complex surface properties pose substantial challenges to their analysis.

View Article and Find Full Text PDF

Babesiosis - a globally emerging tick-borne infectious disease primarily caused by the intraerythrocytic piroplasm parasite, Babesia microti - has traditionally been studied using animal models such as mice. Compared to animal models, microfluidic-based models offer advantages, including direct analysis of human samples (such as patient blood), enhanced assay capacity (including physical/optical access, consistency, and throughput), low costs, and easy adoption. Here, an open microfluidic platform named "µ-Blood" is reported for real-time continuous monitoring B.

View Article and Find Full Text PDF

Microfluidic-based sperm selection is an essential tool recently introduced into assisted reproductive technologies. Conventional approaches such as swim-up and density-gradient centrifugation (DGC) are widely used, however, they lack selectivity and limit the necessary sperm amount in the sample. Moreover, the DGC method has been reported to damage the sperm's DNA, whilst the emerging microfluidic devices offer a soft and flexible way to selectively sort various volumes of raw sperm samples.

View Article and Find Full Text PDF

Surface water, a critical global freshwater resource, faces severe heavy metal contamination threatening ecosystems and human health. Traditional detection methods like ICP-MS are time-consuming and expensive due to complex sample preparation, which is not practical for on-site monitoring. While laser-induced breakdown spectroscopy (LIBS) enables rapid and in situ elemental analysis, its quantitative efficiency in on-site monitoring remains limited by the laborious manual gradient-preparing procedures.

View Article and Find Full Text PDF