A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Quantifying biased response of axon to chemical gradient steepness in a microfluidic device. | LitMetric

Quantifying biased response of axon to chemical gradient steepness in a microfluidic device.

Anal Chem

Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, Hubei 430072, China.

Published: December 2014


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Axons are very sensitive to molecular gradients and can discriminate extremely small differences in gradient steepness. Microfluidic devices capable of generating chemical gradients and adjusting their steepness could be used to quantify the sensitivity of axonal response. Here, we present a versatile and robust microfluidic device that can generate substrate-bound molecular gradients with evenly varying steepness on a single chip to precisely quantify axonal response. In this device, two solutions are perfused into a central channel via two inlets while partially flowing into two peripheral channels through interconnecting grooves, which gradually decrease the fluid velocity along the central channel. Molecular gradients with evenly and gradually decreased steepness can therefore be generated with a high resolution that is less than 0.05%/mm. In addition, the overall distribution range and resolution of the gradient steepness can be highly and flexibly controlled by adjusting various parameters of the device. Using this device, we quantified the hippocampal axonal response to substrate-bound laminin and ephrin-A5 gradients with varying steepnesses. Our results provided more detailed information on how and to what extent different steepnesses guide hippocampal neuron development during the initial outgrowth. Furthermore, our results show that axons can sensitively respond to very shallow laminin and ephrin-A5 gradients, which could effectively initiate biased differentiation of hippocampal neurons in the steepness range investigated in this study.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac504159gDOI Listing

Publication Analysis

Top Keywords

gradient steepness
12
molecular gradients
12
axonal response
12
steepness microfluidic
8
microfluidic device
8
gradients evenly
8
central channel
8
laminin ephrin-a5
8
ephrin-a5 gradients
8
steepness
7

Similar Publications