98%
921
2 minutes
20
Aims: To investigate the validity and reliability of Microsoft Kinect-based head tracker (KHT) for measuring head posture.
Methods: Considering the cervical range of motion (CROM) as a reference, one-dimensional and three-dimensional (1D and 3D) head postures of 12 normal subjects (28-58 years of age; 6 women and 6 men) were obtained using the KHT. The KHT was validated by Pearson's correlation coefficient and intraclass correlation (ICC) coefficient. Test-retest reliability of the KHT was determined by its 95% limit of agreement (LoA) with the Bland-Altman plot. Face recognition success rate was evaluated for each head posture.
Results: Measurements of 1D and 3D head posture performed using the KHT were very close to those of the CROM with correlation coefficients of 0.99 and 0.97 (p<0.05), respectively, as well as with an ICC of >0.99 and 0.98, respectively. The reliability tests of the KHT in terms of 1D and 3D head postures had 95% LoA angles of approximately ±2.5° and ±6.5°, respectively.
Conclusions: The KHT showed good agreement with the CROM and relatively favourable test-retest reliability. Considering its high performance, convenience and low cost, KHT could be clinically used as a head posture-measuring system.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/bjophthalmol-2014-305095 | DOI Listing |
Anat Sci Educ
September 2025
University of Florida College of Medicine, Gainesville, Florida, USA.
Self-efficacy and anatomical knowledge have been shown to be important in the development of medical students. Validated instruments designed to measure the construct of anatomical self-efficacy during the clinical years of medical school are limited. In this study, the Anatomical Self-Efficacy Instrument for Clinical Clerkships (ASEI-CC) was developed, and evidence for the reliability of the scores and the validity of the interpretations of the scores was gathered.
View Article and Find Full Text PDFJ Epidemiol
September 2025
Faculty of Sport Sciences, Waseda University.
Background: Brief measures of 24-hour movement behaviors are needed to easily evaluate their durations. The present study investigated the criterion validity and test-retest reliability of a brief self-report instrument to assess 24-hour movement behaviors.
Methods: A paper-based self-administered questionnaire was used to assess sleep, sedentary behavior (SB), light-intensity physical activity (LPA), and moderate-to-vigorous physical activity (MVPA) with four items in 35 healthy adults.
J Virol Methods
September 2025
Laboratorio de Virología, Facultad de Ciencias Veterinarias, Universidad Nacional de La Plata, Buenos Aires, Argentina. 60 y 118, La Plata (CP 1900), Buenos Aires, Argentina; Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz 2290, CABA, Argentina. Electronic address
The global emergence of SARS-CoV-2 has highlighted the need for rapid, sensitive, and affordable diagnostic tools, not only for human health but also for animal surveillance within a One Health framework. This study aimed to evaluate the performance of a SYBR Green-based real-time quantitative PCR (qPCR) assay for the detection of SARS-CoV-2 from animal samples, focusing on domestic dogs and cats. A total of 140 oropharyngeal swab samples were collected and analyzed using primers targeting a 139-bp fragment of the N gene of SARS-CoV-2.
View Article and Find Full Text PDFAsian Nurs Res (Korean Soc Nurs Sci)
September 2025
Daejeon Eulji University Hospital, Daejeon, South Korea. Electronic address:
Purpose: In this study, we aimed to develop and test the validity and reliability of the Korean version of the Novice Nursing Practitioner Role Transition (K-NNPRT) scale.
Methods: This scale was developed through forward translation, expert panel endorsement, and back translation and revised based on cognitive interviews. Data for the psychometric test were collected from 248 nurses who provide advanced care in Korea.
Int Dent J
September 2025
Department of Periodontology, Oral Medicine and Oral Surgery, Institute for Dental and Craniofacial Sciences, Charité-University Medicine Berlin, Corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany; Department of Conservati
Introduction And Aims: Artificial intelligence (AI) is transforming dental care by enhancing diagnostic accuracy, efficiency, and patient experience. This study aimed to assess dental patients' acceptance, perceptions, and concerns regarding AI-powered diagnosis using the Unified Theory of Acceptance and Use of Technology 2 (UTAUT2) framework through structural equation modelling (SEM).
Methods: A cross-sectional study was conducted among dental patients at King Saud University Dental Hospital, Riyadh.