98%
921
2 minutes
20
Whereas serial measurements of lung function at work and at home are a well-known diagnostic tool for the diagnosis of occupational asthma (OA), little is known about the serial measurements of non-invasive parameters such as exhaled nitric oxide (eNO). A 51-year-old baker with variable shortness of breath without relation to work was examined for suspected OA. Skin prick test showed weak sensitizations to wheat and rye flour (without sensitizations to environmental allergens) that were corroborated by in vitro testing (CAP class 3). Baseline FEV1 of 58% predicted and a decrease of forced expiratory volume in 1 s (FEV1) after placebo (sugar powder) of 17% did not allow inhalational challenge testing. The patient performed daily measurements of FEV1 and eNO for about a month during a holiday at home and at work. Whereas symptoms and FEV1 did not show differences between holidays and work periods, eNO showed a clear increase from below 10 ppb to a maximum of 75 ppb. A diagnosis of baker's asthma was made, and the patient quit his job immediately after medical advice. A year afterwards, the patient was still taking asthma medication, but his symptoms had improved, FEV1 had increased to 73% predicted, and eNO was 25 ppb. We conclude that serial measurements of eNO at home and at work may be a useful tool for the diagnosis of OA.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/5584_2014_67 | DOI Listing |
Neuro Oncol
September 2025
Department of Radiation Oncology, Mayo Clinic, Rochester, MN, USA.
Background: Disruption of the blood-brain barrier (BBB) in high-grade brain tumors is characterized by contrast accumulation on diagnostic imaging. This window of opportunity study correlates contrast imaging features with the tumor distribution of BBB-permeable (levetiracetam) and -impermeable (cefazolin) drugs.
Methods: Patients with a clinical diagnosis of a high-grade brain tumor underwent MRI for surgical planning.
J Am Soc Echocardiogr
September 2025
Division of Cardiovascular Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
The American Society of Echocardiography (ASE) plays a vital role in establishing practice standards and guidelines within the echocardiography field. Its influence is comprehensive, covering training, image acquisition, nomenclature, measurements, diagnosis, and quality improvement. This report focuses on the final phases of the diagnostic imaging process, specifically reporting and communicating exam results.
View Article and Find Full Text PDFRes Rep Urol
August 2025
Department of Preventive Medicine and Biostatistics, Uniformed Services University of the Health Sciences, Bethesda, MD, USA.
Objective: Digital Rectal Examination (DRE) remains an important preventive measure in primary care settings, but a single screening may produce false positives. We sought to explore the trend of abnormal DRE (suspicious and non-suspicious) findings in men with and without prostate cancer.
Methods: We utilized data on 34,756 men (1,713 Black and 33,043 White) from the Prostate, Lung, Colorectal, and Ovarian (PLCO) Cancer Screening Trial.
Front Microbiol
August 2025
Institute of Tuberculosis Prevention and Control, Ningbo Municipal Center for Disease Control and Prevention, Ningbo, China.
Background: The urinary lipoarabinomannan (LAM) assay has emerged as a promising tool for tuberculosis (TB) diagnosis and treatment monitoring. This study aimed to evaluate the diagnostic and monitoring performance of LAM compared to Acid-fast bacilli (AFB), Mycobacteria Growth Indicator Tube (MGIT), and GeneXpert, and to establish its clinical utility in a stratified TB population.
Methods: A prospective cohort study included TB patients stratified by AFB/MGIT status into three groups.
Int J Exerc Sci
September 2025
School of Allied Health Professions, Louisiana State University Health Sciences Center at Shreveport, Shreveport, LA, USA.
Motion analysis is used to measure proper bicycle fit, avoid injury, and improve cycling performance. Small changes in position can impact joint kinematics and risk for overuse injury. Concerns regarding the often-used biomechanical model Plug-in-Gait (PIG) resulted in the creation of Conventional Gait Model 2 (CGM2).
View Article and Find Full Text PDF