Serial measurements of exhaled nitric oxide at work and at home: a new tool for the diagnosis of occupational asthma.

Adv Exp Med Biol

Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr-University Bochum (IPA), 1 Bürkle-de-la-Camp-Platz St., D-44789, Bochum, Germany,

Published: December 2015


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Whereas serial measurements of lung function at work and at home are a well-known diagnostic tool for the diagnosis of occupational asthma (OA), little is known about the serial measurements of non-invasive parameters such as exhaled nitric oxide (eNO). A 51-year-old baker with variable shortness of breath without relation to work was examined for suspected OA. Skin prick test showed weak sensitizations to wheat and rye flour (without sensitizations to environmental allergens) that were corroborated by in vitro testing (CAP class 3). Baseline FEV1 of 58% predicted and a decrease of forced expiratory volume in 1 s (FEV1) after placebo (sugar powder) of 17% did not allow inhalational challenge testing. The patient performed daily measurements of FEV1 and eNO for about a month during a holiday at home and at work. Whereas symptoms and FEV1 did not show differences between holidays and work periods, eNO showed a clear increase from below 10 ppb to a maximum of 75 ppb. A diagnosis of baker's asthma was made, and the patient quit his job immediately after medical advice. A year afterwards, the patient was still taking asthma medication, but his symptoms had improved, FEV1 had increased to 73% predicted, and eNO was 25 ppb. We conclude that serial measurements of eNO at home and at work may be a useful tool for the diagnosis of OA.

Download full-text PDF

Source
http://dx.doi.org/10.1007/5584_2014_67DOI Listing

Publication Analysis

Top Keywords

serial measurements
16
tool diagnosis
12
exhaled nitric
8
nitric oxide
8
work tool
8
diagnosis occupational
8
occupational asthma
8
asthma serial
8
work
6
eno
5

Similar Publications

Background: Disruption of the blood-brain barrier (BBB) in high-grade brain tumors is characterized by contrast accumulation on diagnostic imaging. This window of opportunity study correlates contrast imaging features with the tumor distribution of BBB-permeable (levetiracetam) and -impermeable (cefazolin) drugs.

Methods: Patients with a clinical diagnosis of a high-grade brain tumor underwent MRI for surgical planning.

View Article and Find Full Text PDF

The American Society of Echocardiography (ASE) plays a vital role in establishing practice standards and guidelines within the echocardiography field. Its influence is comprehensive, covering training, image acquisition, nomenclature, measurements, diagnosis, and quality improvement. This report focuses on the final phases of the diagnostic imaging process, specifically reporting and communicating exam results.

View Article and Find Full Text PDF

Objective: Digital Rectal Examination (DRE) remains an important preventive measure in primary care settings, but a single screening may produce false positives. We sought to explore the trend of abnormal DRE (suspicious and non-suspicious) findings in men with and without prostate cancer.

Methods: We utilized data on 34,756 men (1,713 Black and 33,043 White) from the Prostate, Lung, Colorectal, and Ovarian (PLCO) Cancer Screening Trial.

View Article and Find Full Text PDF

Background: The urinary lipoarabinomannan (LAM) assay has emerged as a promising tool for tuberculosis (TB) diagnosis and treatment monitoring. This study aimed to evaluate the diagnostic and monitoring performance of LAM compared to Acid-fast bacilli (AFB), Mycobacteria Growth Indicator Tube (MGIT), and GeneXpert, and to establish its clinical utility in a stratified TB population.

Methods: A prospective cohort study included TB patients stratified by AFB/MGIT status into three groups.

View Article and Find Full Text PDF

Motion analysis is used to measure proper bicycle fit, avoid injury, and improve cycling performance. Small changes in position can impact joint kinematics and risk for overuse injury. Concerns regarding the often-used biomechanical model Plug-in-Gait (PIG) resulted in the creation of Conventional Gait Model 2 (CGM2).

View Article and Find Full Text PDF