98%
921
2 minutes
20
Background: For transcatheter aortic valve implantation (TAVI), transesophageal echocardiography (TEE) and multislice computed tomography (MSCT) measurements of the aortic annulus diameter (AAD) are often regarded as competitive. We evaluated if 1 MSCT method could be interchangeable with TEE measurements.
Methods: We compared AAD measurements performed using TEE, MSCT, and transthoracic echocardiography (TTE) in 129 consecutive patients with severe aortic stenosis (AS) who were referred for TAVI. Using MSCT, AAD was measured in the 3-chamber (3C) view and at the level of the virtual basal ring (mean diameter [MD] of the long-axis [LA] and short-axis [SA] diameters, and AAD derived from the cross-sectional area [CSA] and the circumference). Correlations with echocardiographic measurements and agreement regarding the TAVI strategy (decision to implant and choice of prosthesis size based on manufacturer cutoff recommendations) were assessed.
Results: AAD measured in 3C (intraclass correlation [ICC], 0.79) and MD emphasizing the weight of the SA (MD4 [3 SA + LA/4]; ICC, 0.76) and MD5 [4 SA + LA/5; ICC, 0.75]) provided the highest correlation and the best agreement with TEE (kappa = 0.47, 0.27, and 0.31 respectively). However, TTE provided a better a correlation and agreement with TEE than all MSCT methods (ICC, 0.87; kappa = 0.66). The agreement between MSCT and TEE varied with AAD eccentricity and degree of aortic valve calcification (AVC), but in all subsets, values observed with MSCT never reached those observed with TTE.
Conclusions: MSCT and TEE are measuring different landmarks and consequently MSCT and TEE measurements are not interchangeable. Prospective randomized studies aimed at defining which method provides the best clinical results are clearly needed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.cjca.2014.06.012 | DOI Listing |
J Clin Med
August 2025
Heartcenter Trier, Krankenhaus der Barmherzigen Brueder, 54292 Trier, Germany.
An accurate device sizing for percutaneous left atrial appendage closure (LAAC) can be challenging. Intraprocedural automated LAA evaluation by transoesophageal echocardiography (TEE) based on an artificial intelligence-assisted 3D model may facilitate sizing and prediction of C-arm angulation for device implantation in a one-stop-shop procedure. This study aimed to evaluate the feasibility and accuracy of automated echocardiographic LAA sizing based on a patient-specific 3D heart model prototype in real-time.
View Article and Find Full Text PDFJ Med Biochem
June 2025
Nanjing Medical University, Sir Run Run Hospital, Department of Cardiothoracic Surgery, Nanjing, Jiangsu, China.
Background: We compared the differences in the effects of transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) on hemodynamics, inflammatory stress response, and pain mediators in patients with severe aortic stenosis (AS).
Methods: 204 patients with severe AS treated with transcatheter aortic valve replacement (TAVR) in our hospital were selected as the research subjects from January 2022 to February 2024. Among them, 109 patients received TTE (TTE group), and another 95 received TEE (TEE group).
Kardiologiia
March 2024
Research Institute of Cardiology, Tomsk National Research Medical Center of the Russian Academy of Sciences, Tomsk.
Aim: Comparative analysis of the height of atherosclerotic plaques (AP) in the descending thoracic aorta (TA) according to two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE), and contrast-enhanced multislice computed tomography (MSCT).
Material And Methods: The TA was examined using 2D, 3D TEE and contrast-enhanced MSCT in 34 patients (20 men and 14 women aged 68 [62; 71] years). AP heights were compared using the Bland-Altman method and the Spearman correlation analysis.
Front Cardiovasc Med
March 2024
Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
Background: Understanding complex cardiac anatomy is essential for percutaneous left atrial appendage (LAA) closure. Conventional multi-slice computed tomography (MSCT) and transesophageal echocardiography (TEE) are now supported by advanced 3D printing and virtual reality (VR) techniques for three-dimensional visualization of volumetric data sets. This study aimed to investigate their added value for LAA closure procedures.
View Article and Find Full Text PDFEchocardiography
March 2024
Department of Ultrasound, the First Affiliated Hospital of Wannan Medical College, Wuhu, Anhui, China.