Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: For transcatheter aortic valve implantation (TAVI), transesophageal echocardiography (TEE) and multislice computed tomography (MSCT) measurements of the aortic annulus diameter (AAD) are often regarded as competitive. We evaluated if 1 MSCT method could be interchangeable with TEE measurements.

Methods: We compared AAD measurements performed using TEE, MSCT, and transthoracic echocardiography (TTE) in 129 consecutive patients with severe aortic stenosis (AS) who were referred for TAVI. Using MSCT, AAD was measured in the 3-chamber (3C) view and at the level of the virtual basal ring (mean diameter [MD] of the long-axis [LA] and short-axis [SA] diameters, and AAD derived from the cross-sectional area [CSA] and the circumference). Correlations with echocardiographic measurements and agreement regarding the TAVI strategy (decision to implant and choice of prosthesis size based on manufacturer cutoff recommendations) were assessed.

Results: AAD measured in 3C (intraclass correlation [ICC], 0.79) and MD emphasizing the weight of the SA (MD4 [3 SA + LA/4]; ICC, 0.76) and MD5 [4 SA + LA/5; ICC, 0.75]) provided the highest correlation and the best agreement with TEE (kappa = 0.47, 0.27, and 0.31 respectively). However, TTE provided a better a correlation and agreement with TEE than all MSCT methods (ICC, 0.87; kappa = 0.66). The agreement between MSCT and TEE varied with AAD eccentricity and degree of aortic valve calcification (AVC), but in all subsets, values observed with MSCT never reached those observed with TTE.

Conclusions: MSCT and TEE are measuring different landmarks and consequently MSCT and TEE measurements are not interchangeable. Prospective randomized studies aimed at defining which method provides the best clinical results are clearly needed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cjca.2014.06.012DOI Listing

Publication Analysis

Top Keywords

msct tee
12
msct
9
aortic annulus
8
annulus diameter
8
transesophageal echocardiography
8
multislice computed
8
aortic valve
8
tee
8
tee msct
8
aad measured
8

Similar Publications

An accurate device sizing for percutaneous left atrial appendage closure (LAAC) can be challenging. Intraprocedural automated LAA evaluation by transoesophageal echocardiography (TEE) based on an artificial intelligence-assisted 3D model may facilitate sizing and prediction of C-arm angulation for device implantation in a one-stop-shop procedure. This study aimed to evaluate the feasibility and accuracy of automated echocardiographic LAA sizing based on a patient-specific 3D heart model prototype in real-time.

View Article and Find Full Text PDF

Background: We compared the differences in the effects of transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) on hemodynamics, inflammatory stress response, and pain mediators in patients with severe aortic stenosis (AS).

Methods: 204 patients with severe AS treated with transcatheter aortic valve replacement (TAVR) in our hospital were selected as the research subjects from January 2022 to February 2024. Among them, 109 patients received TTE (TTE group), and another 95 received TEE (TEE group).

View Article and Find Full Text PDF

Aim: Comparative analysis of the height of atherosclerotic plaques (AP) in the descending thoracic aorta (TA) according to two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE), and contrast-enhanced multislice computed tomography (MSCT).

Material And Methods: The TA was examined using 2D, 3D TEE and contrast-enhanced MSCT in 34 patients (20 men and 14 women aged 68 [62; 71] years). AP heights were compared using the Bland-Altman method and the Spearman correlation analysis.

View Article and Find Full Text PDF

Background: Understanding complex cardiac anatomy is essential for percutaneous left atrial appendage (LAA) closure. Conventional multi-slice computed tomography (MSCT) and transesophageal echocardiography (TEE) are now supported by advanced 3D printing and virtual reality (VR) techniques for three-dimensional visualization of volumetric data sets. This study aimed to investigate their added value for LAA closure procedures.

View Article and Find Full Text PDF
Article Synopsis
  • Transcatheter aortic valve replacement (TAVR) is increasingly used for patients who are not suitable for traditional surgery due to various health issues.
  • This study analyzed data from 70 patients with severe aortic regurgitation (AR) to assess the effectiveness of echocardiography in predicting post-TAVR complications.
  • Results showed that echocardiographic measurements closely matched CT findings, and preprocedural right bundle branch block (RBBB) significantly increased the risk for needing a pacemaker after the procedure.
View Article and Find Full Text PDF