Article Abstract

Background: The benefit of novel implantable cardioverter defibrillator (ICD) programming in reducing inappropriate ICD therapy and mortality was demonstrated in Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT). However, the cause of mortality reduction remains incompletely evaluated. We aimed to identify factors associated with mortality, with focus on ICD therapy and programming in the MADIT-RIT population.

Methods And Results: In MADIT-RIT, 1500 patients with a primary prophylactic indication for ICD or cardiac resynchronization therapy with defibrillator were randomized to 1 of 3 different ICD programming arms: conventional programming (ventricular tachycardia zone ≥170 beats per minute), high-rate programming (ventricular tachycardia zone ≥200 beats per minute), and delayed programming (60-second delay before therapy ≥170 beats per minute). Multivariate Cox models were used to assess the influence of time-dependent appropriate and inappropriate ICD therapy (shock and antitachycardia pacing) and randomized programming arm on all-cause mortality. During an average follow-up of 1.4±0.6 years, 71 of 1500 (5%) patients died: cardiac in 40 patients (56.3%), noncardiac in 23 patients (32.4%), and unknown in 8 patients (11.3%). Appropriate shocks (hazard ratio, 6.32; 95% confidence interval, 3.13-12.75; P<0.001) and inappropriate therapy (hazard ratio, 2.61; 95% confidence interval, 1.28-5.31; P=0.01) were significantly associated with an increased mortality risk. There was no evidence of increased mortality risk in patients who experienced appropriate antitachycardia pacing only (hazard ratio, 1.02; 95% confidence interval, 0.36-2.88; P=0.98). Randomization to conventional programming was identified as an independent predictor of death when compared with patients randomized to high-rate programming (hazard ratio, 2.0; 95% confidence interval, 1.06-3.71; P=0.03).

Conclusions: In MADIT-RIT, appropriate shocks, inappropriate ICD therapy, and randomization to conventional ICD programming were independently associated with an increased mortality risk. Appropriate antitachycardia pacing was not related to an adverse outcome.

Clinical Trial Registration Url: clinicaltrials.gov Unique identifier: NCT00947310.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCEP.114.001623DOI Listing

Publication Analysis

Top Keywords

icd therapy
12
beats minute
12
mortality reduction
8
implantable cardioverter
8
cardioverter defibrillator
8
programming
8
multicenter automatic
8
automatic defibrillator
8
defibrillator implantation
8
implantation trial-reduce
8

Similar Publications

Eating disorders are primarily associated with women and an obsession with thinness. Recent research and social media content show that men are also concerned about their body image, striving for a muscular and athletic physique. To investigate eating disorder tendencies among male content creators with a mesomorphic body type (N = 26), a social media analysis was conducted on Instagram and TikTok over four weeks.

View Article and Find Full Text PDF

Background: Chagas heart disease (ChD) is a significant public health concern in Latin America, contributing to a high incidence of sudden cardiac death (SCD). Despite advances in heart failure treatment, management of Chagas cardiomyopathy has not progressed accordingly. While ICDs are effective for primary and secondary prevention in other conditions, patients with ChD often experience more frequent episodes of ventricular tachycardia, and ICD use may provide a negative impact and increase mortality.

View Article and Find Full Text PDF

Introduction: Time to initiation of therapy in oncological care is an influential factor in disease progression and survival outcomes in many cancer types. We aim to identify factors associated with delayed time to treatment (TTT) in high-grade osteosarcoma and its relationship to disease-specific survival (DSS).

Methods: The SEER database was queried for biopsy-confirmed cases of high-grade osteosarcoma between 2000 and 2021 using ICD-O-3 histology codes 9180/3-9194/3 and primary site codes C40.

View Article and Find Full Text PDF

Defect engineering in cobalt-doped prussian blue to enhance sonocatalytic activities for anticancer treatment.

J Mater Chem B

September 2025

Key Laboratory of Photochemical Biomaterials and Energy Storage Materials, College of Chemistry and Chemical Engineering, Harbin Normal University, Harbin 150025, China.

The effect of sonocatalysis on anticancer treatment is always restricted by rapid recombination of charge and low utilization of the ultrasonic cavitation effect. Herein, cobalt-doped prussian blue (PB) nanocubes were synthesized, and then they were etched by acidic solution to obtain amorphous Co-FePB@1h with abundant defects including: Fe/Co defects, Fe-(CN) vacancies, and dangling bonds. Both doping and defect engineering contribute to decreasing the band gap and promoting charge separation.

View Article and Find Full Text PDF

The COVID-19 pandemic necessitated a triad of therapies for patients: oxygen, nutrition, and patient positioning. In the progressive care units, patients were placed in a prone position while receiving continuous enteral nutrition (EN) to optimize healing and oxygenation. The study aimed to identify the rate of aspiration pneumonia in non-ventilated COVID-19 patients placed in a prone position while receiving continuous EN.

View Article and Find Full Text PDF