A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Implantation of 2 trabecular microbypass stents in a patient with primary open-angle glaucoma refractory to previous glaucoma-filtering surgeries. | LitMetric

Implantation of 2 trabecular microbypass stents in a patient with primary open-angle glaucoma refractory to previous glaucoma-filtering surgeries.

J Cataract Refract Surg

From the Faculty of Medicine and Dentistry (Roelofs) and the Department of Ophthalmology (Arora, Dorey), University of Alberta, Edmonton, Alberta, Canada. Electronic address:

Published: August 2014


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Unlabelled: A 77-year-old woman with primary open-angle glaucoma was referred for surgical evaluation after failing to achieve target intraocular pressure (IOP) despite previous combined phacotrabeculectomy and Ahmed valve implantations. The IOP prior to surgery was 28 mm Hg on topical dorzolamide-timolol, latanoprost, and brimonidine. Trabecular bypass surgery with implantation of 2 iStents was performed. The IOP decreased by 11 mm Hg to 17 mm Hg after surgery and has remained stable for 2 years. This is the first published case reporting this magnitude of IOP reduction sustained for more than 2 years following insertion of 2 trabecular microbypass stents in a patient who had previous glaucoma-filtering surgeries. Further prospective studies are needed to establish expanded surgical indications for implantation of trabecular microbypass stents.

Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2014.06.017DOI Listing

Publication Analysis

Top Keywords

trabecular microbypass
12
implantation trabecular
8
microbypass stents
8
stents patient
8
primary open-angle
8
open-angle glaucoma
8
previous glaucoma-filtering
8
glaucoma-filtering surgeries
8
patient primary
4
glaucoma refractory
4

Similar Publications