Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The intra-aortic balloon pump (IABP), which is the main representative of the counterpulsation technique, has been an invaluable tool in cardiologists' and cardiac surgeons' armamentarium for approximately half a century. The IABP confers a wide variety of vaguely understood effects on cardiac physiology and mechano-energetics. Although, the recommendations for its use are multiple, most are not substantially evidence-based. Indicatively, the results of recently performed prospective studies have put IABP's utility in the setting of post-infarction cardiogenic shock into question. However, the particular issue remains open to further research. IABP support in high-risk patients undergoing PCI is associated with favorable long-term clinical outcome. In cardiac surgery, the use of IABP in cases of peri-operative low-output syndrome, refractory angina or ischemia-related mechanical complications is a usual, but poorly justified strategy. Anecdotal cases of treatment of incessant ventricular arrhythmias, reversal of right ventricular dysfunction and partial myocardial recovery have also been reported with its use. Converging data demonstrate the potential of safe long-term IABP support as a bridge to decision making or a bridge to transplantation modality in patients with heart failure. The feasibility of IABP insertion via other than the femoral artery sites enhances this potential. Despite the fact that several other counterpulsation devices have been developed and tested overtime none has managed to substitute the IABP, which continues to be most frequently used mechanical assist device.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2014.01.098DOI Listing

Publication Analysis

Top Keywords

iabp support
8
iabp
7
counterpulsation concept
4
concept remarkable
4
remarkable established
4
established challenging
4
challenging future
4
future intra-aortic
4
intra-aortic balloon
4
balloon pump
4

Similar Publications

Aims: Cardiogenic shock remains a significant cause of mortality despite multiple advancements in medical interventions. Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) provides crucial circulatory support but also increases left ventricular (LV) after-load, potentially worsening outcomes. Effective LV unloading strategies can enhance patient survival during VA-ECMO treatment.

View Article and Find Full Text PDF

Aims: Non-pharmacological therapies for acute decompensated heart failure (HF) and cardiogenic shock have evolved considerably in recent decades. Short-term mechanical circulatory support (MCS) devices can be used as circulatory backup. While nearly all available devices use continuous flow, evidence indicates that pulsatile flow can be more effective.

View Article and Find Full Text PDF

An electrical storm (ES) represents one of cardiology's most formidable and life-threatening crises, marked by relentless ventricular arrhythmias within a 24-hour period. While stimulant cardiotoxicity is an escalating concern, the devastating role of methamphetamine in triggering refractory ES and its deleterious outcomes in advanced cardiomyopathy, particularly within the critical care setting, remains profoundly underreported and poorly understood. We present the urgent case of a 44-year-old male with end-stage dilated cardiomyopathy and chronic, heavy methamphetamine abuse, who spiraled into incessant ventricular tachycardia (VT) storm following acute methamphetamine use.

View Article and Find Full Text PDF

Pathophysiologic assumptions and clinical data frame a promising role for intra-aortic balloon pump (IABP) in heart failure-related cardiogenic shock (HF-CS). Currently, two randomized clinical trials (RCT) exploring this hypothesis have been published, yielding inconclusive results. We thus designed this meta-analysis to assess the efficacy of IABP in HF-CS.

View Article and Find Full Text PDF