A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Quantitative analysis of trazodone in human plasma by using HPLC-fluorescence detector coupled with strong cation exchange chromatographic column: application to a pharmacokinetic study in Chinese healthy volunteers. | LitMetric

Quantitative analysis of trazodone in human plasma by using HPLC-fluorescence detector coupled with strong cation exchange chromatographic column: application to a pharmacokinetic study in Chinese healthy volunteers.

J Chromatogr B Analyt Technol Biomed Life Sci

Clinical Pharmacy and Pharmacology Research Institute, The Second Xiangya Hospital, Central South University, 139# Middle Renmin Road, Changsha, Hunan Province 410011, PR China; School of Pharmaceutical Sciences, Central South University, Changsha, Hunan Province 410013, PR China.

Published: January 2014


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A simple, selective, and sensitive high performance liquid chromatography (HPLC) procedure has been developed for determination of trazodone in human plasma. Prazosin was employed as the internal standard (IS). Sample preparation involved liquid-liquid extraction by methyl tert-butyl ether after alkalinization with ammonia. The HPLC separation was performed on a CAPCELL PAK SCX column (250mm×4.6mm, 5.0μm, Shiseido, Japan) with a mobile phase of acetonitrile/80mmol/L ammonium phosphate (pH adjusted to 6.0) (60:40, v/v) at a flow rate of 1.2mL/min. The peaks were detected by using fluorescence detector (excitation wavelength 320nm and emission wavelength 440nm). The extraction recovery was 72.6-88.3% and the method was over the concentration range of 5.0-2486ng/mL with a lower limit of quantitation (LLOQ) of 5.0ng/mL using 300μL of plasma. The intra- and inter-day accuracy of the method at three concentrations ranged from 96.7% to 104.2% for trazodone with precision of 2.9-3.7%. This validated method was successfully applied to a pharmacokinetic study enrolling 12 Chinese volunteers administered a single oral trazodone hydrochloride extended-release tablet of 75mg.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2013.11.013DOI Listing

Publication Analysis

Top Keywords

trazodone human
8
human plasma
8
pharmacokinetic study
8
quantitative analysis
4
trazodone
4
analysis trazodone
4
plasma hplc-fluorescence
4
hplc-fluorescence detector
4
detector coupled
4
coupled strong
4

Similar Publications