A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Modeling of porous scaffold deformation induced by medium perfusion. | LitMetric

Modeling of porous scaffold deformation induced by medium perfusion.

J Biomed Mater Res B Appl Biomater

School of Chemical Engineering, Oklahoma State University, Stillwater, Oklahoma, 74078.

Published: May 2014


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this study, we tested the possibility of calculating permeability of porous scaffolds utilized in soft tissue engineering using pore size and shape. We validated the results using experimental measured pressure drop and simulations with the inclusion of structural deformation. We prepared Polycaprolactone (PCL) and Chitosan-Gelatin (CG) scaffolds by salt leaching and freeze drying technique, respectively. Micrographs were assessed for pore characteristics and mechanical properties. Porosity for both scaffolds was nearly same but the permeability varied 10-fold. Elastic moduli were 600 and 9 kPa for PCL and CG scaffolds, respectively, while Poisson's ratio was 0.3 for PCL scaffolds and ∼1.0 for CG scaffolds. A flow-through bioreactor accommodating a 10 cm diameter and 0.2 cm thick scaffold was used to determine the pressure-drop at various flow rates. Additionally, computational fluid dynamic (CFD) simulations were performed by coupling fluid flow, described by Brinkman equation, with structural mechanics using a dynamic mesh. The experimentally obtained pressure drop matched the simulation results of PCL scaffolds. Simulations were extended to a broad range of permeabilities (10(-10) m(2) to 10(-14) m(2) ), elastic moduli (10-100,000 kPa) and Poisson's ratio (0.1-0.49). The results showed significant deviation in pressure drop due to scaffold deformation compared to rigid scaffold at permeabilities near healthy tissues. Also, considering the scaffold as a nonrigid structure altered the shear stress profile. In summary, scaffold permeability can be calculated using scaffold pore characteristics and deformation could be predicted using CFD simulation. These relationships could potentially be used in monitoring tissue regeneration noninvasively via pressure drop.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.33054DOI Listing

Publication Analysis

Top Keywords

pressure drop
16
pcl scaffolds
12
scaffold deformation
8
pore characteristics
8
elastic moduli
8
poisson's ratio
8
scaffold
7
scaffolds
7
modeling porous
4
porous scaffold
4

Similar Publications