98%
921
2 minutes
20
Vertical flow systems filled with porous medium have been shown to efficiently remove volatile organic contaminants (VOCs) from contaminated groundwater. To apply this semi-natural remediation strategy it is however necessary to distinguish between removal due to biodegradation and due to volatile losses to the atmosphere. Especially for (potentially) toxic VOCs, the latter needs to be minimized to limit atmospheric emissions. In this study, numerical simulation was used to investigate quantitatively the removal of volatile organic compounds in two pilot-scale water treatment systems: an unplanted vertical flow filter and a planted one, which could also be called a vertical flow constructed wetland, both used for the treatment of contaminated groundwater. These systems were intermittently loaded with contaminated water containing benzene and MTBE as main VOCs. The highly dynamic but permanently unsaturated conditions in the porous medium facilitated aerobic biodegradation but could lead to volatile emissions of the contaminants. Experimental data from porous material analyses, flow rate measurements, solute tracer and gas tracer test, as well as contaminant concentration measurements at the boundaries of the systems were used to constrain a numerical reactive transport modeling approach. Numerical simulations considered unsaturated water flow, transport of species in the aqueous and the gas phase as well as aerobic degradation processes, which made it possible to quantify the rates of biodegradation and volatile emissions and calculating their contribution to total contaminant removal. A range of degradation rates was determined using experimental results of both systems under two operation modes and validated by field data obtained at different operation modes applied to the filters. For both filters, simulations and experimental data point to high biodegradation rates, if the flow filters have had time to build up their removal capacity. For this case volatile emissions are negligible and total removal can be attributed to biodegradation, only. The simulation study thus supports the use of both of these vertical flow systems for the treatment of groundwater contaminated with VOCs and the use of reactive transport modeling for the assessment of VOCs removal and operation modes in these high performance treatment systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jconhyd.2013.07.007 | DOI Listing |
J Ultrasound Med
September 2025
Department of Fetal Medicine, Fortis Hospital, Ludhiana, India.
We present two cases highlighting novel prenatal ultrasound findings in atretic cephalocele (AC) using high-resolution ultrasound and microvascular flow imaging. This report includes the first prenatal ultrasound demonstration of key diagnostic AC features: superior sagittal sinus fenestration, observed in the parietal case, and a fibrous dural stalk, identified in both parietal and occipital cases. Both fetuses presented with a small midline scalp lesion, internal echoes, and an underlying bony defect without brain tissue herniation.
View Article and Find Full Text PDFFront Immunol
September 2025
Institute of Human Virology, University of Maryland School of Medicine, Baltimore, MD, United States.
Innate-like T cells (ILT), including γδ T cells (Vδ2s), Natural Killer T cells (NKTs) and Mucosal-associated Invariant T cells (MAITs), integrate innate and adaptive immunity, playing important roles in homeostatic conditions as well as during infection or inflammation. ILT are present on both sides of the fetal-maternal interface, but our knowledge of their phenotypical and functional features in neonates is limited. Using spectral flow cytometry we characterized cord blood ILT in neonates born to healthy women and women living with HIV.
View Article and Find Full Text PDFJ Acoust Soc Am
September 2025
State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240, China.
This paper presents a semi-analytical method, referred to as the linear-velocity-profile fast field program (LFFP), for predicting two-dimensional sound fields in ambient parallel mean flows. The proposed method incorporates the linear velocity layering method into the fundamental framework of fast field program (FFP) to achieve reduced computational costs and enhanced precision, particularly under high-velocity gradient conditions. The accuracy of LFFP is validated through a two-dimensional jet case by comparison with the linearized Euler equation in frequency-domain.
View Article and Find Full Text PDFSmall
September 2025
Department of Mechanical Engineering, University of Alberta, 9211-116 Street NW, Edmonton, Alberta, T6G 1H9, Canada.
Rapid strides in portable electronics and telecommunication technologies have sharply escalated the demand for high-performance electromagnetic interference (EMI) shielding materials that effectively suppress secondary electromagnetic pollution while simultaneously integrating thermal management. Here an innovative, lightweight, hierarchical triple-layer aerogel structure comprising nickel (Ni) foam (NiF), titanium carbonitride (TiCNT) MXene, and poly(vinyl alcohol) (PVA), fabricated via a facile, one-step bidirectional freeze-casting process is presented. This asymmetric aerogel architecture strategically employs an impedance-matching MXene/PVA top layer for optimized microwave entry, a NiF/MXene/PVA interlayer introducing magnetic loss and enhancing heat conduction, and a reflective, thermally foamed MXene bottom layer promoting internal reflection for superior energy absorption.
View Article and Find Full Text PDFEnviron Manage
September 2025
Centro Interdisciplinario de Investigaciones y Estudios sobre Medio Ambiente y Desarrollo (CIIEMAD), Instituto Politécnico Nacional (IPN), Calle 30 de Junio de 1520, Mexico City, México.
This study evaluates the hydrogeochemical behavior and groundwater quality under significant anthropogenic pressure in a volcanic-carbonate aquifer, using trace elements and Rare Earth Elements (REE) as environmental tracers. A total of 25 samples from wells of different depths and flow rates in the city of Puebla were analyzed by ICP-MS. Positive Ce anomalies (18 samples with an average of 1.
View Article and Find Full Text PDF