98%
921
2 minutes
20
Nanotechnology based on the highly specific pairing of nucleobases in DNA has been used to generate a wide variety of well-defined two- and three-dimensional assemblies, both static and dynamic. However, control over the junction angles to achieve them has been limited. To achieve higher order assemblies, the strands of the DNA duplex are typically made to deviate at junctions with configurations based on crossovers or non-DNA moieties. Such strand crossovers tend to be intrinsically unstructured with the overall structural rigidity determined by the architecture of the nanoassembly, rather than the junction itself. Specific approaches to define nanoassembly junction angles are based either on the cooperative twist- and strain-promoted tuning of DNA persistence length leading to bent DNA rods for fairly large nano-objects, or de novo synthesis of individual junction inserts that are typically non-DNA and based on small organic molecules or metal-coordinating ligand moieties. Here, we describe a general strategy for direct control of junction angles in DNA nanostructures that are completely tunable about the DNA helix. This approach is used to define angular vertices through readily accessible backbone-branched DNAs (bbDNAs). We demonstrate how such bbDNAs can be used as a new building block in DNA nanoconstruction to obtain well-defined nanostructures. Angular control through readily accessible bbDNA building block provides a general and versatile approach for incorporating well-defined junctions in nanoconstructs and expands the toolkit toward achieving strain free, highly size- and shape-tunable DNA based architectures.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/nn305787m | DOI Listing |
J Am Chem Soc
September 2025
Department of Chemistry and Biochemistry, University of Delaware, Newark, Delaware 19716, United States.
Among the different types of HIV-1 maturation inhibitors, those that stabilize the junction between the capsid protein C-terminal domain (CA) and the spacer peptide 1 (SP1) within the immature Gag lattice are promising candidates for antiretroviral therapies. Here, we report the atomic-resolution structure of CA-SP1 assemblies with the small-molecule maturation inhibitor PF-46396 and the assembly cofactor inositol hexakisphosphate (IP6), determined by magic angle spinning (MAS) NMR spectroscopy. Our results reveal that although the two PF-46396 enantiomers exhibit distinct binding modes, they both possess similar anti-HIV potency.
View Article and Find Full Text PDFJ Vis Exp
August 2025
Tianjin Union Medical Center, The First Affiliated Hospital of Nankai University;
Posterior lumbar screw fixation is the most common surgical method for lumbar disc herniation, but patients often face multiple complications postoperatively. The occurrence of screw track loosening can lead to fusion failure and even life-threatening screw track extrusion. However, there is currently a lack of animal models specifically targeting changes in the screw track following lumbar screw fixation.
View Article and Find Full Text PDFPurpose: This study aims to validate the usefulness of T10-pelvic angle (T10PA) in predicting pelvic tilt (PT) restoration, proximal junctional kyphosis (PJK) development, and clinical outcomes after adult spinal deformity (ASD) surgery.
Methods: This retrospective study included 213 ASD patients who underwent fusion from the lower thoracic spine (T9 or T10) to the pelvis. T10PA was measured on 6-week postoperative radiographs as the angle between the center of T10 and the hip center, and from the hip center to the midpoint of the S1 upper endplate.
Ann Anat
September 2025
Department of Anatomy, School of Medicine, Faculty of Health Sciences, National and Kapodistrian University of Athens, Greece; "VARIANTIS" Research Laboratory, Department of Clinical Anatomy, Mazovian Academy in Plock, Poland.
Background: The vertebral artery (VA) undergoes a critical anatomical transition as it pierces the dura mater at the craniocervical junction. Precise knowledge of dural penetration patterns and angulation is essential for diagnostic imaging, neurosurgical planning, and minimizing iatrogenic risk in posterior fossa procedures.
Methods: This retrospective imaging study evaluated 100 adult patients who underwent 1.
Spine (Phila Pa 1976)
September 2025
Department of Orthopedic Surgery, Warren Alpert Medical School of Brown University, Providence, Rhode Island.
Study Design: Retrospective analysis of prospective data.
Objective: Evaluate the impact of radiographic and morphologic configuration of the uppermost instrumented vertebrae (UIV) region on proximal junctional kyphosis (PJK) rates.
Background: Literature is limited on evaluation of the preoperative landing zone (UIV-1 to UIV +2 levels) and its impact on development of PJK.