Article Abstract

A fully automated point-of-care testing (POCT) system with a surface acoustic wave (SAW) immunosensor was developed for rapid and sensitive detection of cardiac troponin I (cTnI) in body fluid (plasma and whole blood). The assay, based on gold nanoparticle sandwich immunoassay and subsequent gold staining, was performed on the SAW immunosensor packaged inside a disposable microfluidic cartridge. The entire fluidic process, including plasma separation, reagent transport, metering, and mixing, was carried out by controlling the centrifugal force acting on the rotating cartridge and laser-irradiated ferrowax microvalves. On investigation of sensor response to various cTnI concentrations, the system exhibited a high performance with a detection limit of 6.7 pg mL(-1), and the coefficient of variation was less than 10% over the entire test range (10 pg mL(-1) to 25 ng mL(-1)). On comparing this POCT system with a clinically utilized system in a physical laboratory (Centaur® XP; Siemens), a correlation coefficient of 0.998 was found, validating the diagnostic capability of the SAW immunosensor.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c3an00182bDOI Listing

Publication Analysis

Top Keywords

point-of-care testing
8
system surface
8
surface acoustic
8
acoustic wave
8
cardiac troponin
8
poct system
8
system
5
centrifugally actuated
4
actuated point-of-care
4
testing system
4

Similar Publications

Rational design of tunable pH switches through shadow-strand hybridization-actuated displacement engineering.

Nucleic Acids Res

September 2025

Key Laboratory of Clinical Laboratory Diagnostics (Chinese Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing 400016, P. R. China.

Local pH variations play a pivotal role in numerous critical biological processes. However, achieving the tunability and selectivity of pH detection remains a challenge. Here, we present a DNA-based strategy that enables programmable and selective pH responses, which is termed shadow-strand hybridization-actuated displacement engineering (SHADE).

View Article and Find Full Text PDF

Mycoplasma pneumonia, a primary aetiological agent of atypical pneumonia, necessitates the implementation of rapid point-of-care diagnostics. Lateral flow immunoassays (LFIAs) hold promise for point-of-care testing (POCT), yet their sensitivity levels are frequently constrained by probe affinity and matrix interference. We introduce an orientational labelling strategy that employs magnetic nanoparticles (MNPs) functionalized with staphylococcal protein A (SPA) to simultaneously enhance antibody orientation and facilitate magnetic enrichment.

View Article and Find Full Text PDF

Endocrinologist-led genomic testing for monogenic diabetes in adult diabetes clinics: a feasibility and outcome study.

Diabetes Res Clin Pract

September 2025

St Vincent's Clinical Campus, School of Clinical Medicine, Faculty of Medicine and Health, University of New South Wales, Wallace Wurth Building (C27), Cnr High St & Botany St, Kensington, Sydney 2052 NSW, Australia; Clinical Genomics, St Vincent's Hospital Sydney, Translational Research Centre, 97-

Aims: Monogenic diabetes (MGD), such as Maturity-Onset Diabetes of the Young (MODY), is under-recognised and under-diagnosed. Accurate diagnosis of MGD requires genetic testing and has important treatment implications. Integrating MGD testing within diabetes clinics can increase testing uptake and MGD diagnosis.

View Article and Find Full Text PDF

Background: Unsupervised cognitive assessments are becoming commonly used in studies of aging and neurodegenerative diseases. As assessments are completed in everyday environments and without a proctor, there are concerns about how common distractions may impact performance and whether these distractions may differentially impact those experiencing the earliest symptoms of dementia.

Objective: We examined the impact of self-reported interruptions, testing location, and social context during testing on remote cognitive assessments in older adults.

View Article and Find Full Text PDF

Background: Acute respiratory infections (ARIs) are frequent reasons for medical consultations in general practice and can lead to unnecessary recontacts. Introducing new point-of-care (POC) polymerase chain reaction (PCR) diagnostic equipment may offer an attractive and efficient way of providing a more precise and exact microbial diagnosis. Successful uptake of POC PCR equipment could potentially lead to a reduction in recontacts with benefits for both staff and patients.

View Article and Find Full Text PDF