98%
921
2 minutes
20
Background: The aim of this study was to compare beat frequency measurements of ependymal cilia made by digital high speed imaging to those obtained using the photomultiplier and modified photodiode techniques. Using high speed video analysis the relationship of the power and recover strokes was also determined.
Methods: Ciliated strips of ependyma attached to slices from the brain of Wistar rats were incubated at 30°C and observed using a ×50 water immersion lens. Ciliary beat frequency was measured using each of the three techniques: the high speed video, photodiode and photomultiplier. Readings were repeated after 30 minutes incubation at 37°C. Ependymal cilia were observed in slow motion and the precise movement of cilia during the recovery stroke relative to the path travelled during the power stroke was measured.
Results: The mean (95% confidence intervals) beat frequencies determined by the high speed video, photomultiplier and photodiode at 30°C were 27.7 (26.6 to 28.8), 25.5 (24.4 to 26.6) and 20.8 (20.4 to 21.3) Hz, respectively. The mean (95% confidence intervals) beat frequencies determined by the high speed video, photomultiplier and photodiode at 37°C were 36.4 (34 to 39.5), 38.4 (36.8 to 39.9) and 18.8 (16.9 to 20.5) Hz. The inter and intra observer reliability for measurement of ciliary beat frequency was 3.8% and 1%, respectively. Ependymal cilia were observed to move in a planar fashion during the power and recovery strokes with a maximum deviation to the right of the midline of 12.1(11.8 to 13.0)° during the power stroke and 12.6(11.6 to 13.6)° to the left of the midline during the recovery stroke.
Conclusion: The photodiode technique greatly underestimates ciliary beat frequency and should not be used to measure ependymal ciliary beat frequency at the temperatures studied. Ciliary beat frequency from the high speed video and photomultiplier techniques cannot be used interchangeably. Ependymal cilia had minimal deviation to the right side during their power stroke and to the left during the recovery stroke.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3555703 | PMC |
http://dx.doi.org/10.1186/2046-2530-1-8 | DOI Listing |
Am J Hypertens
September 2025
New York State Psychiatric Institute, New York NY.
Background: Blood pressure (BP) is not steady. It varies over intervals from months to consecutive cardiac cycles and this variation contains meaningful information beyond mean BP. Variability over multiple clinic visits (VVV-BP) and during 24-hour ambulatory monitoring (ABPV) is positively related to risk of stroke and coronary artery disease and negatively associated with cognitive performance.
View Article and Find Full Text PDFHeart Rhythm
August 2025
National Heart and Lung Institute, Imperial College, London, United Kingdom; Department of Internal Medicine and Cardiology, Masaryk University, Brno, Czech Republic. Electronic address:
Heart rate belongs to the most essential clinical indices assessed in virtually every patient. It is also well known, although certainly not so widely utilized, that in addition to the mean frequency of cardiac periods, their variability provides further clinical indicators. The predictive value of low heart rate variability (HRV) is nothing new.
View Article and Find Full Text PDFbioRxiv
August 2025
Department of Physiology & Membrane Biology, School of Medicine, University of California, Davis, USA.
Pacemaker myocytes of the sinoatrial (SA) node initiate each heartbeat through coupled voltage and Ca oscillators, but whether ATP supply is regulated on a beat-by-beat schedule in these cells has been unclear. Using genetically encoded sensors targeted to the cytosol and mitochondria, we tracked beat-resolved ATP dynamics in intact mouse SA node and isolated myocytes. Cytosolic ATP rose transiently with each Ca transient and segregated into high- and low-gain phenotypes defined by the Ca-ATP coupling slope.
View Article and Find Full Text PDFHumans spontaneously synchronize movements to a perceived underlying pulse, or beat, in music. Beat perception may be indexed by the synchronization of neural oscillations to the beat, marked by increases in EEG amplitude at the beat frequency [Nozaradan, S., Peretz, I.
View Article and Find Full Text PDFHear Res
August 2025
Department of Psychology, University of Minnesota, Minneapolis, 75 East River Parkway, Minneapolis, MN 55455, USA.
The enjoyment of music can be severely disrupted when instruments or voices are out of tune with each other. Both hearing loss and aging may degrade pitch perception, potentially affecting the ability to detect mistuning. For younger listeners with normal hearing, mistuning perception in music relies on both beats (amplitude fluctuations between closely spaced frequency components) and inharmonicity (non-integer frequency relationships between components from different sources).
View Article and Find Full Text PDF