Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
We report the development of a method to analyze receptor and β-arrestin2 mobilization between Class A and B GPCRs via time-resolved fluorescent microscopy coupled with semiautomated high-content multiparametric analysis. Using transiently expressed, tagged β2-adrenergic receptor (β₂-AR) or parathyroid hormone receptor type 1 (PTH₁R), we quantified trafficking of the receptors along with the mobilization and colocalization of coexpressed tagged β-arrestin2. This classification system allows for exclusion of cells with nonoptimal characteristics and calculation of multiple morphological and spatial parameters including receptor endosome formation, β-arrestin mobilization, colocalization, areas, and shape. Stimulated Class A and B receptors demonstrate dramatically different patterns with regard to β-arrestin interactions. The method provides high kinetic resolution measurement of receptor translocation, which allows for the identification of the fleeting β-arrestin interaction found with β₂-AR agonist stimulation, in contrast to stronger mobilization and receptor colocalization with agonist stimulation of the PTH₁R. Though especially appropriate for receptor kinetic studies, this method is generalizable to any dual fluorescence probe system in which quantification of object formation and movement is desired. These methodologies allow for quantitative, unbiased measurement of microscopy data and are further enhanced by providing real-time kinetics.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4169994 | PMC |
http://dx.doi.org/10.1017/S1431927612014067 | DOI Listing |