A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Bloch surface wave-enhanced fluorescence biosensor. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A new approach to signal amplification in fluorescence-based assays for sensitive detection of molecular analytes is reported. It relies on a sensor chip carrying a one-dimensional photonic crystal (1DPC) composed of two piled up segments which are designed to increase simultaneously the excitation rate and the collection efficiency of fluorescence light. The top segment supports Bloch surface waves (BSWs) at the excitation wavelength and the bottom segment serves as a Bragg mirror for the emission wavelength of used fluorophore labels. The enhancement of the excitation rate on the sensor surface is achieved through the resonant coupling to BSWs that is associated with strong increase of the field intensity. The increasing of collection efficiency of fluorescence light emitted from the sensor surface is pursued by using the Bragg mirror that minimizes its leakage into a substrate and provides its beaming toward a detector. In order to exploit the whole evanescent field of BSW, extended three-dimensional hydrogel-based binding matrix that is functionalized with catcher molecules is attached to 1DPC for capturing of target analyte from a sample. Simulations supported by experiments are presented to illustrate the design and determined the performance characteristics of BSW-enhanced fluorescence spectroscopy. A model immunoassay experiment demonstrates that the reported approach enables increasing signal to noise ratio, resulting in about one order of magnitude improved limit of detection (LOD) with respect to regular total internal reflection fluorescence (TIRF) configuration.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2012.12.001DOI Listing

Publication Analysis

Top Keywords

bloch surface
8
excitation rate
8
collection efficiency
8
efficiency fluorescence
8
fluorescence light
8
bragg mirror
8
sensor surface
8
fluorescence
5
surface wave-enhanced
4
wave-enhanced fluorescence
4

Similar Publications