A pseudo-matched filter for chaos.

Chaos

Department of Physics, Duke University, Durham, North Carolina 27708, USA.

Published: September 2012


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A matched filter maximizes the signal-to-noise ratio of a signal. In the recent work of Corron et al. [Chaos 20, 023123 (2010)], a matched filter is derived for the chaotic waveforms produced by a piecewise-linear system. This system produces a readily available binary symbolic dynamics that can be used to perform correlations in the presence of large amounts of noise using the matched filter. Motivated by these results, we describe a pseudo-matched filter, which operates similarly to the original matched filter. It consists of a notch filter followed by a first-order, low-pass filter. We compare quantitatively the matched filter's performance to that of our pseudo-matched filter using correlation functions. On average, the pseudo-matched filter performs with a correlation signal-to-noise ratio that is 2.0 dB below that of the matched filter. Our pseudo-matched filter, though somewhat inferior in comparison to the matched filter, is easily realizable at high speed (>1 GHz) for potential radar applications.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4754437DOI Listing

Publication Analysis

Top Keywords

matched filter
24
pseudo-matched filter
20
filter
12
signal-to-noise ratio
8
matched
7
pseudo-matched
5
filter chaos
4
chaos matched
4
filter maximizes
4
maximizes signal-to-noise
4

Similar Publications

Background: Frequent premature atrial complexes (PACs) can increase the risk of atrial fibrillation or atrial tachycardia, and pharmacological therapy can be challenging.

Objective: To report the use of three-dimensional electro-anatomical mapping of PAC originating from the right atrial free wall and treatment by radiofrequency ablation in three horses.

Study Design: Retrospective case report.

View Article and Find Full Text PDF

3D imaging based on phase-shifting structured light is widely used in industrial measurement due to its non-contact nature. However, it typically requires a large number of additional images (multi-frequency heterodyne (M-FH) method) or introduces intensity features that compromise accuracy (space domain modulation phase-shifting (SDM-PS) method) for phase unwrapping, and it remains sensitive to motion. To overcome these issues, this article proposes a nonlinear phase coding-based stereo phase unwrapping (NPC-SPU) method that requires no additional patterns while maintaining measurement accuracy.

View Article and Find Full Text PDF

Background: Cerebrovascular reactivity reflects changes in cerebral blood flow in response to an acute stimulus and is reflective of the brain's ability to match blood flow to demand. Functional MRI with a breath-hold task can be used to elicit this vasoactive response, but data validity hinges on subject compliance. Determining breath-hold compliance often requires external monitoring equipment.

View Article and Find Full Text PDF

Reconstructing time-domain data from discontinuous Percept™ PC and RC output using external data acquisition and linear filtering.

J Neurosci Methods

September 2025

Center for Neurological Restoration, Neurological Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, United States of America.

Background: The Medtronic Percept™ PC and RC are deep brain stimulation (DBS) systems with recording capability. However, when the stimulation frequency is changed, the recordings were segmented, introducing interruptions that shift each segment in the time domain.

New Method: Ex-vivo, stimulation frequency was changed while local field potential was being recorded in both leads.

View Article and Find Full Text PDF

Transfusion support for sensitized patients is an important function of blood centers and HLA laboratories. However, access to widely available software to facilitate matching patients with compatible donor units is limited. We developed vendor-supported and integrated software that interfaces with the laboratory informatics system, sourcing typing data from our platelet donor registry and retrieving patient HLA typing and unacceptable antibody specificities.

View Article and Find Full Text PDF