Isotropic fractionation is a quantitative technique that allows reliable estimates of absolute numbers of neuronal and non-neuronal brain cells. However, being fast for single small brains, it requires a long time for processing large brains or many small ones, if done manually. To solve this problem, we developed a machine to automate the method, and tested its efficiency, consistency, and reliability as compared with manual processing. The machine consists of a set of electronically controlled rotation and translation motors coupled to tissue grinders, which automatically transform fixed tissue into homogeneous nuclei suspensions. Speed and torque of the motors can be independently regulated by electronic circuits, according to the volume of tissue being processed and its mechanical resistance to fractionation. To test the machine, twelve paraformaldehyde-fixed rat brains and eight human cerebella were separated into two groups, respectively: one processed automatically and the other, manually. Both pairs of groups (rat and human tissue) followed the same, published protocol of the method. We compared the groups according to nuclei morphology, degree of clustering and number of cells. The machine proved superior for yielding faster results due to simultaneous processing in multiple grinders. Quantitative analysis of machine-processed tissue resulted in similar average numbers of total brain cells, neurons, and non-neuronal cells, statistically similar to the manually processed tissue and equivalent to previously published data. We concluded that the machine is more efficient because it utilizes many homogenizers simultaneously, equally consistent in producing high quality material for counting, and quantitatively reliable as compared to manual processing.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jneumeth.2012.09.015DOI Listing

Publication Analysis

Top Keywords

isotropic fractionation
8
brain cells
8
compared manual
8
manual processing
8
tissue
7
machine
5
automatic isotropic
4
fractionation large-scale
4
large-scale quantitative
4
quantitative cell
4

Similar Publications

The management of localized choroidal melanoma generally involves definitive radiation therapy when globe preservation is feasible. Stereotactic radiosurgery (SRS) using the Gamma Knife system (Elekta AB, Stockholm, Sweden) or the CyberKnife system (Accuray Inc., Madison, WI, USA) is a well-established radiation modality for treating choroidal melanoma, with outcomes comparable to those of other radiation techniques.

View Article and Find Full Text PDF

Purpose: To demonstrate the extended capabilities of 3D multi-slab diffusion-weighted acquisition (3D-msDWI) on high-performance gradients (HPG) to support advanced microstructure modeling for in-vivo human studies at high resolutions.

Methods: Despite optimal SNR-efficiency, the application of 3D-msDWI has been limited by the long volume acquisition times (VAT) required for encoding the 3D k-space using multi-shot approaches. Substantial reduction of VAT is possible by employing optimized 3D k-space under-sampling methods.

View Article and Find Full Text PDF

Background And Purpose: MR-guided adaptive radiation therapy allows for daily plan adaptation to account for anatomical changes. Two common strategies are adapt-to-position (ATP), involving re-optimization based on isocenter shifts, and adapt-to-shape (ATS), involving full recontouring and reoptimization. This study provides a dosimetric comparison of ATP and ATS using accumulated dose.

View Article and Find Full Text PDF

Effects of temperature anisotropy in a hard sphere gas.

Phys Rev E

July 2025

Indian Institute of Technology Bombay, Department of Chemical Engineering, Powai, Mumbai 400076, India.

We consider the effects of temperature anisotropy in a quiescent, hard sphere gas, as a model system for flowing granular matter. Utilising kinetic theory we obtain expressions for the streaming pressure, collisional pressure and the rate of transfer of kinetic energy between the different translational degrees of freedom, assuming a Maxwell-Boltzmann velocity distribution and an isotropic pair correlation function at contact. A theory for the collisional pressure with an anisotropic pair correlation function is also presented.

View Article and Find Full Text PDF

Quantitative MRI (qMRI) enables objective, reproducible measurement of tissue-specific MR properties, offering improved diagnostic accuracy and deeper insight into disease mechanisms compared to conventional MRI. Parameters such as proton density (PD), relaxation rates (R1, R2), and myelin volume fraction (MVF) provide valuable information on tissue composition, water content, and myelination. Reference qMRI atlases based on these parameters are essential for identifying deviations in individuals and supporting clinical decision-making.

View Article and Find Full Text PDF