A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

[Depth of focus in spherical and aspheric intraocular lenses]. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To investigate depth of focus (DOF) in spherical and aspheric IOL eye models.

Methods: Computer numerical simulation experiment was used. IOL eye model based on Liou-Brennan eye model was constructed by using ZEMAX optical design software. Different IOL were implanted in this eye model. Monochromatic through focus modulation transfer function (MTF) curves were computed. Pupil and aspheric designs' effect on DOF were analyzed.

Results: DOF of eye model increased with pupil shrinkage in 550 nm monochromatic light (FY60AD 1.20 D at 6 mm pupil, 1.35 D at 5 mm pupil, 1.70 D at 4 mm pupil, 2.46 D at 3 mm pupil; YA60BBR 1.24 D at 6 mm pupil, 1.48 D at 5 mm pupil, 1.80 D at 4 mm pupil, 2.50 D at 3 mm pupil). MTF in spherical IOL eye model was higher with minus defocus, this trend was obvious at larger pupil. MTF of aspheric IOL eyes were higher than spherical IOL eyes when well focused at 5 mm pupil, while the DOF was lower in aspheric IOL with negative spherical aberration (Tecnis Z9000 1.31 D, FY60AD 1.35 D, CeeOn911 1.55 D, YA60BBR 1.48 D). DOF decreased less in aspheric IOL with zero spherical aberration (LI61AO 1.42 D).

Conclusions: DOF in IOL eye model was higher at smaller pupil. When the pupil was large, well focused aspheric IOL improved optical quality compared with spherical IOL, while DOF and the tolerance to defocus in aspheric IOL were partially lost; this phenomenon was obvious with minus defocus.