A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

[Preparation and application of a colloidal gold strip to detect the rabies antibody]. | LitMetric

[Preparation and application of a colloidal gold strip to detect the rabies antibody].

Sheng Wu Gong Cheng Xue Bao

Key Laboratory of Jilin Provice for Zoonosis Prevention and Control, Institute of Military Veterinary, Academy of Military Medical Science, Changchun 130122, China.

Published: May 2011


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

To develop a specific, rapid, and convenient immunochromatography assay (ICA) to detect the rabies antibody in clinical sample from immuned dogs by rabies vaccine. Colloidal gold particles labeled with purified rabies virus (CVS11) were used as the detector reagent. The staphylococcal protein A (SPA) and pured rabbit anti-rabies virus IgG were blotted on the test and control regions of nitrocellulose membrane. Then the strip was assembled with sample pad, absorbing pad, and dorsal shield. The assay samples (261 dog's serum) were collected from Wildlife Rabies Disease Diagnostic Laboratories of Ministry of Agriculture in China, Institute of Military Veterinary, Academy of Military Medical Sciences and other six provinces, including rabies virus positive and negative serum. The performance of the strip was compared to fluorescent antibody virus neutralization test. The neutralizing antibody titer could be detected above 0.5 IU. The strip did not change of performance when stored at room temperature for 12 months. It may offer reference of neutralizing antibody titer level after dogs immuned rabies vaccine and determin whether the dogs need to be immuned again.

Download full-text PDF

Source

Publication Analysis

Top Keywords

colloidal gold
8
detect rabies
8
rabies vaccine
8
rabies virus
8
neutralizing antibody
8
antibody titer
8
dogs immuned
8
rabies
7
[preparation application
4
application colloidal
4

Similar Publications