Background: Assessment of the functional significance of left anterior descending coronary artery (LAD) stenosis of intermediate severity (50%-70% diameter stenosis) is challenging. The aim of this study was to compare the value of noninvasive coronary flow reserve (CFR) with that of invasive fractional flow reserve (FFR) in the setting of LAD stenosis of angiographic intermediate severity.

Methods: Fifty stable consecutive patients (mean age, 63 ± 13 years; 11 women; mean left ventricular ejection fraction, 61 ± 10%) with angiographic proximal LAD stenoses of intermediate severity (55.5 ± 5% diameter stenosis on quantitative coronary angiography), no previous anterior myocardial infarction, and various vascular risk factors were prospectively studied. They underwent FFR assessment with intracoronary bolus adenosine (150 μg), and CFR assessment using intravenous adenosine (140 μg/kg/min over 2 min) in the distal part of the LAD on the same day in nearly all patients. CFR was defined as hyperemic peak diastolic LAD flow velocity divided by baseline flow velocity (normal value >2), and FFR was defined as distal pressure divided by mean aortic pressure during maximal hyperemia (normal value >0.8).

Results: The mean FFR and CFR were 0.84 ± 0.07 and 2.7 ± 0.75, respectively, in the whole population. Concordant results between FFR and CFR were seen in 44 patients (88%) and discordant results in six patients (12%). There was a significant correlation between CFR and FFR (r = 0.59, P < .01). A better correlation was found between FFR and percentage LAD diameter stenosis, and lesion length (all P values < .05), than between CFR and the same anatomic markers of stenosis severity (all P values = NS). The sensitivity, specificity, and positive and negative predictive values of CFR >2 to detect a nonsignificant lesion defined by normal FFR were 95%, 69%, 90%, and 82%, respectively.

Conclusions: In patients with LAD stenosis of intermediate severity, discordant results between noninvasive CFR and FFR were not unusual, and the anatomic determinants of the stenosis were better correlated to FFR than to CFR. However, CFR, which is a global evaluation of the coronary tree, has very high sensitivity to detect a nonsignificant lesion, despite the high prevalence of vascular risk factors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.echo.2010.12.007DOI Listing

Publication Analysis

Top Keywords

flow reserve
16
intermediate severity
16
stenosis intermediate
12
lad stenosis
12
diameter stenosis
12
ffr cfr
12
cfr
11
ffr
10
stenosis
9
coronary flow
8

Similar Publications

Importance: Right anomalous aortic origin of a coronary artery (R-AAOCA) is a rare congenital condition increasingly diagnosed with the growing use of cardiac imaging. Due to dynamic compression of the anomalous vessel, invasive fractional flow reserve (FFR) during a dobutamine-atropine volume challenge (FFR-dobutamine) is considered the reference standard. A reliable alternative method is needed to reduce extensive invasive testing, but it remains uncertain whether noninvasive imaging can accurately assess the hemodynamic relevance of R-AAOCA.

View Article and Find Full Text PDF

Background: The benefits of physiology-guided management in acute coronary syndrome (ACS) remain inconclusive due to limited evidence. In our FAVOR III China trial, a quantitative flow ratio (QFR)-based physiology-guided strategy versus standard angiography guidance improved the 1-year primary outcome among participants with coronary artery disease (CAD). We aimed to investigate, in a prespecified analysis, the outcomes of QFR-based physiological guidance in the FAVOR III China participants with low-risk ACS.

View Article and Find Full Text PDF

Validation of angiography-based FFR in non-culprit vessels of patients presenting with STEMI.

Clin Res Cardiol

September 2025

Department of (Interventional) Cardiology, Thoraxcenter, Erasmus University Medical Center, Room Rg-628, P.O. Box 2040, 3000 CA, Rotterdam, the Netherlands.

Background: Fractional flow reserve (FFR) for non-culprit lesions (NCLs) in patients with ST-elevation myocardial infarction (STEMI) can be influenced by temporary changes in microvascular resistance. Angiography-derived vessel fractional flow reserve (vFFR) has been tested as a less-invasive alternative.

Aims: The FAST STEMI II study aimed to assess the diagnostic performance of acute-setting vFFR vs.

View Article and Find Full Text PDF

Background: Invasive coronary physiology including fractional flow reserve (FFR), instantaneous wave-free ratio (iFR), and coronary flow reserve (CFR) are guideline-endorsed tools to guide the management of coronary artery disease (CAD). Complex factors impact and confound these assessments, and discordance between modalities complicates clinical management. iEquate is a prospective observational trial that combines multi-modality coronary physiology and optical coherence tomography (OCT) to identify the determinants of pressure-wire derived myocardial ischemia and iFR-FFR discordance.

View Article and Find Full Text PDF

Emerging biosensor technologies for obstructive sleep apnea: A comprehensive overview and future prospects.

Prog Mol Biol Transl Sci

September 2025

Division of Sleep Medicine, Louis Stokes Cleveland VA Medical Center, Cleveland, OH, United States; Division of Pulmonary, Critical Care, and Sleep Medicine, University Hospitals Cleveland Medical Center, Cleveland, OH, United States; Department of Medicine, Case Western Reserve University, Clevelan

Obstructive sleep apnea (OSA) is a pervasive disorder characterized by recurrent airway obstructions during sleep. OSA carries serious health risks, such as cardiovascular and cognitive impairments, and imposes a significant economic burden. This chapter provides a comprehensive overview of various biosensors currently employed for OSA detection, including in-lab polysomnography and flow-based home sleep apnea testing.

View Article and Find Full Text PDF