Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: Intermittent bolus propofol is an effective agent for pediatric magnetic resonance imaging sedation but requires constant vigilance and dose titration. Magnetic resonance imaging-compatible infusion pumps may make it possible to continuously infuse propofol, achieving a steady level of sedation at a lower total dose. This study investigates total propofol dose, recovery time, and magnetic resonance image quality in children receiving intermittent vs. continuously infused propofol sedation in children undergoing brain and spine magnetic resonance imaging studies.

Design: An open-label, prospective, randomized, controlled study. A single-blinded radiologist rated the quality of magnetic resonance images.

Setting: Children's hospital pediatric radiology sedation center.

Patients: One hundred seventy children age 1 month to 18 yrs undergoing deep sedation for brain, spine, or both brain and spine magnetic resonance imaging.

Interventions: After informed consent, patients were randomly assigned to two groups: group 1 (intermittent) received a propofol bolus of 2-4 mg/kg, followed by repeat boluses of 0.5-2 mg/kg/dose as needed. Group C (continuous) received a bolus of propofol 2-4 mg/kg, followed by a continuous infusion of 100 μg/kg/min with 1-mg/kg/dose boluses with drip titration to effect.

Measurements And Main Results: Patient demographics, sedation risk assessment, propofol dose, sedation recovery times, incidence of complications, and quality of the magnetic resonance imaging studies were measured. A total of 170 children were enrolled in the study, with 75 in group C and 95 in group I. Both groups were similar with regard to age, weight, gender, and magnetic resonance imaging study type. Group C required a lesser dose of propofol (132 ± 54 μg/kg/min) compared to (162 ± 74 μg/kg/min) in that required in group I (p = .018). There were no differences between the two groups with regard to quality of the imaging study, recovery time, or incidence of complications.

Conclusions: Compared to intermittent bolus dosing, continuous propofol infusion provides lesser dose exposure without impacting recovery time or quality of the magnetic resonance imaging study.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PCC.0b013e31820ab881DOI Listing

Publication Analysis

Top Keywords

magnetic resonance
40
resonance imaging
24
brain spine
16
spine magnetic
12
recovery time
12
quality magnetic
12
imaging study
12
propofol
10
magnetic
10
resonance
10

Similar Publications

Aims: The aim of this observational study is to describe the use of epiduroscopy to decrease the enlargement of the ligamentum flavum (LF) in patients with spinal stenosis, as well as the selection of the appropriate patient and the safety measures that enhance procedural success.

Materials & Methods: We introduce the patient selection protocol, define the appropriate indication and the safety measures to use the epiduroscopy as a tool to decrease the size of the LF and increase space, reducing possible complications.

Results: Among patients included in the study, there were no cases of access difficulty or coccydynia, and one case of urinary incontinence occurred in a patient with Schizas grade D (very severe) stenosis.

View Article and Find Full Text PDF

Chikungunya virus (CHIKV) typically causes febrile illness and arthralgia. However, severe complications such as encephalitis, rhabdomyolysis, and multiorgan dysfunction are increasingly recognised, particularly during epidemics in endemic regions. We report a case of a 61-year old male presenting with progressive flaccid paraparesis and respiratory failure following febrile illness.

View Article and Find Full Text PDF

Importance: Recent longitudinal studies in patients with unruptured intracranial aneurysms (UIAs) suggested that aneurysm wall enhancement (AWE) on magnetic resonance imaging (MRI) predicts growth and rupture. However, because these studies were limited by small sample size and short follow-up duration, it remains unclear whether this radiological biomarker has predictive value for UIA instability.

Objective: To determine the 4-year risk of instability of UIAs with AWE and investigate whether AWE is an independent predictor of UIA instability.

View Article and Find Full Text PDF

Metastatic involvement (MB) of the breast from extramammary malignancies is rare, with an incidence of 0.09-1.3% of all breast malignancies.

View Article and Find Full Text PDF

Background: Electrical impedance myography (EIM) has been proposed as an efficient, non-invasive biomarker of muscle composition in facioscapulohumeral muscular dystrophy (FSHD).

Objective: We investigate whether EIM parameters are associated with muscle structure measured by magnetic resonance imaging (MRI), muscle histology, and transcriptomic analysis as well as strength at the individual leg muscle level.

Methods: We performed a multi-center cross-sectional study enrolling 33 patients with FSHD.

View Article and Find Full Text PDF