Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background/aims: Interventional radiologists have played a main role in the technical evolution of gastrostomy, from the first surgical/endoscopical approaches to percutaneous interventional procedures. This study evaluated the results obtained in a 12-year series.

Methods: During the period December 1996 to December 2008, 254 new consecutive gastrostomies and 275 replacement procedures were performed in selected patients. All of the cases were treated by a T-fastener gastropexy and tube placement. The procedures were assessed by analyzing indications, patient selection, duration of the procedures, and mortality.

Results: All 254 first gastrostomies were successful; replacement procedures were also successfully performed. One (0.2%) patient with severe neurologic disorders died after the procedure without signs of procedure-related complications, and seven (1.3%) major complications occurred (four duodenal lesions with peritoneal leakage, two gastric bleedings, and one gastric lesion). Minor complications were easily managed; three tube ruptures were resolved.

Conclusions: This long-term series and follow-up showed that a group of interventional radiologist can effectively provide gastrostomy placement and long-term tube management. Percutaneous gastrostomy is less invasive than other approaches and it satisfies the needs even of high-risk patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2989545PMC
http://dx.doi.org/10.5009/gnl.2010.4.S1.S44DOI Listing

Publication Analysis

Top Keywords

replacement procedures
8
procedures performed
8
procedures
5
percutaneous radiologic
4
gastrostomy
4
radiologic gastrostomy
4
gastrostomy 12-year
4
12-year series
4
series background/aims
4
background/aims interventional
4

Similar Publications

Kommerell's diverticulum (KD) combined with a right-sided aortic arch (RAA) and an aberrant left subclavian artery (ALSA) is a rare congenital vascular anomaly causing significant compressive dysphagia. Treatment options, including open surgery, thoracic endovascular aortic repair and hybrid approaches, are debated due to anatomical complexities. We report a 48-year-old female with dysphagia from symptomatic KD, RAA and ALSA, clearly delineated by preoperative computed tomography angiography.

View Article and Find Full Text PDF

Complete detachment of the aortic root following a Bentall procedure is an exceptionally rare complication. The vast majority of reported cases are secondary to prosthetic valve endocarditis or underlying vasculitis. Currently, the most reliable treatment for aortic root dehiscence-particularly in the context of prosthetic valve endocarditis-is repeat root replacement, typically via a second Bentall procedure or with the use of a homograft or allograft.

View Article and Find Full Text PDF

The sterile insect technique (SIT) is a highly effective biologically-based method for the suppression of many insect pest populations. SIT efficacy could be improved by methods of male sterilization that avoid the use of irradiation that can result in diminished fitness and mating competitiveness. Alternative sterilization methods include conditional disruption of genes for male fertility, or using their sperm-specific promoters to drive the expression of genes for lethal effectors.

View Article and Find Full Text PDF

Introduction: Patients with aortic aneurysms are at elevated risk of rupture, dissection and death during and after transcatheter aortic valve repair (TAVR), often requiring consideration for endovascular aneurysm repair (EVAR) at the time of TAVR. However, data comparing outcomes of simultaneous versus staged TAVR-EVAR are limited.

Methods: Using the National Inpatient Sample between the years 2018 and 2021, we compared in-hospital outcomes of simultaneous and staged TAVR-EVAR.

View Article and Find Full Text PDF

Background: Bacillus thuringiensis Cry toxins are well known for their insecticidal properties, primarily through the formation of ion-leakage pores via α4-α5 hairpins. His178 in helix 4 of the Cry4Aa mosquito-active toxin has been suggested to play a crucial role in its biotoxicity.

Objective: This study aimed to investigate the functional importance of Cry4Aa-His178 through experimental and computational analyses.

View Article and Find Full Text PDF