Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Cases of self-inserted foreign bodies in the male urethra and urinary bladder are unusual. In most cases, the type of foreign body can be identified by taking a history or from radiological findings; sometimes, however, it is difficult to identify the foreign body because of decreased mental capacity of the patient or unknown radiological characteristics of the foreign body. We experienced a chronic alcoholic patient with septicemia and penile necrosis in whom a fragment of mirror glass had passed through the urethra into the bladder. The glass, 2 cm in length and 0.7 cm in diameter, was detected by cystoscopy and was removed by using a resectosope.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2855477PMC
http://dx.doi.org/10.4111/kju.2010.51.2.149DOI Listing

Publication Analysis

Top Keywords

foreign body
16
penile necrosis
8
foreign
5
delayed diagnosis
4
diagnosis intraurethral
4
intraurethral foreign
4
body
4
body causing
4
causing urosepsis
4
urosepsis penile
4

Similar Publications

Purpose: Primary ventral hernia repair is a common elective procedure; however, mesh placement practices vary widely, and there is limited evidence to guide optimal placement. This international study examined surgeons' preferences and considerations regarding mesh placement in elective primary ventral hernia repair.

Methods: We conducted an international cross-sectional survey targeting surgeons experienced in primary ventral hernia repair.

View Article and Find Full Text PDF

Purpose: To present a case of synthetic intrastromal corneal ring segment (ICRS) intrusion secondary to necrosis and migration, managed by implantation of corneal allogenic intrastromal ring segments (CAIRS) within the preexisting tunnel.

Methods: A 24-year-old man with known keratoconus underwent bilateral ICRS implantation. He presented with blurred vision in the right eye 6 weeks after the procedure.

View Article and Find Full Text PDF

Purpose: To evaluate tilt, decentration, and axial stability of the Clareon toric intraocular lens (TIOL) (CNW0T3-9; Alcon Laboratories, Inc) over a 6-month follow-up period.

Methods: A single-center, prospective, interventional clinical trial was conducted with a study population of 130 eyes from 82 patients who received a Clareon TIOL. Tilt, decentration, and the aqueous depth were determined preoperatively and at 1 week and 6 months postoperatively using anterior segment optical coherence tomography (Casia 2; Tomey Corporation).

View Article and Find Full Text PDF

Rationale: Gastric bezoar-induced duodenal obstruction represents a rare clinical entity with <0.5% incidence among mechanical bowel obstructions.

Patient Concerns: A 73-year-old female patient presented to our institution, manifesting acute abdominal syndrome characterized by progressive pain and distension.

View Article and Find Full Text PDF

Disruption of the central venous port catheter was identified on the chest radiograph of a 36-year-old woman who had undergone chemotherapy following resection of her colon cancer. Computed tomography revealed that the catheter was impacted in the peripheral pulmonary artery. Instead of using a snare wire, a balloon catheter was inserted into the lumen of the disrupted catheter due to its tight lodging in the pulmonary artery.

View Article and Find Full Text PDF