98%
921
2 minutes
20
A number of studies have shown increased accuracy of pedicle screw placement in spine with the help of computer-assisted navigation. The literature is lacking in regard to functional benefit derived from this technique. The aim of this systematic review was to look at the functional outcomes following computer-assisted pedicle screw placement in spine. A 'Dialog Datastar' search was used using optimized search strategy covering the period from 1950 to July 2009; 23 papers were finally included which met our inclusion criteria. We report on a total of 1,288 patients with 5,992 pedicle screws. The comparison of neurological complications in two groups demonstrated an odds ratio of 0.25 (95% CI 0.06, 1.14) in favour of using navigation for pedicle screw insertion (p = 0.07). Comparative trials demonstrated a significant advantage in terms of accuracy of navigation over conventional pedicle screw insertion with a relative risk of 1.12 (95% CI 1.09, 1.15) (p < 0.00001). Navigation does not show statistically significant benefit in reducing neurological complications and there was insufficient data in the literature to infer a conclusion in terms of fusion rate, pain relief and health outcome scores.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2899753 | PMC |
http://dx.doi.org/10.1007/s00586-009-1258-4 | DOI Listing |
Spine Deform
September 2025
Spine Unit, Department of Orthopedic Surgery, Rigshospitalet, Inge Lehmanns Vej 6, 2100, Copenhagen, Denmark.
Study Design: This is a retrospective single-center study.
Purpose: The purpose is to investigate the incidence of distal junctional kyphosis (DJK) when fused proximal to the stable sagittal vertebra (SSV) in adolescent idiopathic scoliosis (AIS) patients undergoing selective thoracic fusion.
Methods: We retrospectively reviewed a consecutive cohort of surgically treated AIS patients with Lenke 1-2 A/B curves between 2011 and 2022 with a minimum of 2 years of follow-up.
Medicine (Baltimore)
September 2025
Department of Neurological Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
The cervicothoracic junction (CTJ) presents a surgical challenge due to its transitional nature from mobile to rigid segments. Therefore, the biomechanical characteristics of this transitional zone must be taken into consideration during instrumentation. This study aimed to determine the efficacy of the cervical pedicle screw placement (CPS) combined with 5.
View Article and Find Full Text PDFEur Spine J
September 2025
Department of Orthopedics, First Affiliated Hospital of Jinan University, Guangzhou, China.
J Vis Exp
August 2025
Tianjin Union Medical Center, The First Affiliated Hospital of Nankai University;
Posterior lumbar screw fixation is the most common surgical method for lumbar disc herniation, but patients often face multiple complications postoperatively. The occurrence of screw track loosening can lead to fusion failure and even life-threatening screw track extrusion. However, there is currently a lack of animal models specifically targeting changes in the screw track following lumbar screw fixation.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
December 2025
Faculdade de Ciências Médicas de Alagoas, Vascular and Endovascular Surgery Division, Alagoas, Alagoas, Brazil.
Background: Iatrogenic thoracic aortic injury (TAI) is a rare but well-recognized complication of spine surgery, lacking standardized treatment guidelines due to its rarity and variability of manifestations.
Methods: We present a new case of TAI successfully managed with endovascular repair and systematically reviewed 52 articles (1991-2024) reporting 64 cases, including demographics, surgical indications, injury patterns, and treatments.
Results: A 53-year-old man with a T7 fracture underwent posterior spinal instrumentation and developed chest pain due to a combination of impingement and screw penetration into the thoracic aorta and was treated with thoracic endovascular aortic repair (TEVAR) and removal of pedicle screws.