A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Model development and validation of personal exposure to volatile organic compound concentrations. | LitMetric

Model development and validation of personal exposure to volatile organic compound concentrations.

Environ Health Perspect

Division of Environmental Health and Risk Management, School of Geography, Earth, and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham, United Kingdom.

Published: October 2009


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Direct measurement of exposure to volatile organic compounds (VOCs) via personal monitoring is the most accurate exposure assessment method available. However, its wide-scale application to evaluating exposures at the population level is prohibitive in terms of both cost and time. Consequently, indirect measurements via a combination of microenvironment concentrations and personal activity diaries represent a potentially useful alternative.

Objective: The aim of this study was to optimize a model of personal exposures (PEs) based on microenvironment concentrations and time/activity diaries and to compare modeled with measured exposures in an independent data set.

Materials: VOC PEs and a range of microenvironment concentrations were collected with active samplers and sorbent tubes. Data were supplemented with information collected through questionnaires. Seven models were tested to predict PE to VOCs in 75% (n = 370) of the measured PE data set, whereas the other 25% (n = 120) was used for validation purposes.

Results: The best model able to predict PE with independence of measurements was based upon stratified microenvironment concentrations, lifestyle factors, and individual-level activities. The proposed model accounts for 40-85% of the variance for individual VOCs and was validated for almost all VOCs, showing normalized mean bias and mean fractional bias below 25% and predicting 60% of the values within a factor of 2.

Conclusions: The models proposed identify the most important non-weather-related variables for VOC exposures; highlight the effect of personal activities, use of solvents, and exposure to environmental tobacco smoke on PE levels; and may assist in the development of specific models for other locations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2790512PMC
http://dx.doi.org/10.1289/ehp.0900561DOI Listing

Publication Analysis

Top Keywords

microenvironment concentrations
16
exposure volatile
8
volatile organic
8
personal
5
concentrations
5
model
4
model development
4
development validation
4
validation personal
4
exposure
4

Similar Publications