Background: Although attenuation correction (AC) has been successfully applied to large field of view (LFOV) cameras, applicability to small field of view (SFOV) cameras is a concern due to truncation. This study compared perfusion images between a LFOV and SFOV camera with truncation compensation, using the same AC solution.
Methods And Results: Seventy-eight clinically referred patients underwent rest-stress single-photon emission computed tomography (SPECT) using both a SFOV and LFOV camera in a randomized sequence. Blinded images were interpreted by a consensus of three experienced readers. The percentage of normal images for SFOV and LFOV was significantly higher with than without AC (72% vs 44% and 72% vs 49%, both P < .001). Interpretive agreement between cameras was better with than without AC (kappa = 0.736 to 0.847 vs 0.545 to 0.774). Correlation for the summed stress score was higher with than without AC (r (2) = 0.892 vs 0.851, both P < 0.001) while Bland Altman analysis demonstrated narrower limits with than without AC (4.0 to -4.3 vs 5.9 to -5.6).
Conclusion: Attenuation correction using truncation compensation with a SFOV camera yields similar results to a LFOV camera. The higher interpretive agreement between cameras after attenuation correction suggests that such images are preferable to non-attenuation-corrected images.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12350-008-9022-4 | DOI Listing |
J Epidemiol
September 2025
Tohoku Medical Megabank Organization, Tohoku University.
Background: More research is needed to clarify the health effects of dietary carotenoid intakes, and this requires the use of high-quality assessments of habitual dietary intake. Cohort studies from the Tohoku Medical Megabank Organization included a self-administered food frequency questionnaire (TMM-FFQ) for community-dwelling adults. This study evaluated the validity of carotenoid intakes derived from the TMM-FFQ using serum carotenoid concentrations as the gold standard.
View Article and Find Full Text PDFUltrasonics
August 2025
College of Biomedical Engineering, Fudan University, Shanghai 200438, China; State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai 200438, China; Poda Medical Technology Co., Ltd., Shanghai 200433, China. Electronic address:
Transcranial ultrasound localization microscopy (t-ULM) is faced with challenges posed by the skull, including acoustic attenuation and phase aberrations. There is a significant request for an efficient aberration correction method achieving a great balance between computational complexity and accuracy. In this study, the ray theory is first applied to in-vivo transcranial imaging to calculate the traveltime table in the inhomogeneous medium model of the imaging region.
View Article and Find Full Text PDFAppl Radiat Isot
September 2025
Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering (IFIN-HH), 30 Reactorului Str., PO Box MG-6, Magurele, Ilfov County, RO-077125, Romania. Electronic address:
In this work we study the effect of the matrix of the source on the spectrum and on the full energy peak efficiency for low energy photons. Using realistic simulations carried out with PENELOPE 2018, including detector resolution, we show that small angle Compton scattering does contribute to the peak count rate, implying the dependence of the matrix effects on the linear attenuation coefficient μ and also on the scattering cross section. We show that the effect of Compton scattering can be removed from the apparent peak, resulting a "clean" peak depending only on μ.
View Article and Find Full Text PDFAnesth Analg
September 2025
From the Department of Neurosurgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands.
Background: Transcranial electrical stimulation muscle-recorded motor evoked potentials (Tc-mMEPs) are used to monitor the spinal cord motor tracts during spinal surgery. There is considerable intra- and interindividual variability in the signals recorded, causing a high incidence of false positive warnings. Inadequate blood pressure is commonly blamed for false positive warnings and is usually managed with fluid and vasopressor therapy.
View Article and Find Full Text PDFJ Am Chem Soc
September 2025
Hunan Joint International Research Center for Carbon Dioxide Resource Utilization, School of Physics, Central South University, Changsha, Hunan 410083, China.
Single-atom Ni catalysts hold great promise for the acidic CO reduction reaction (CORR), owing to their high CO selectivity. However, their performance under industrially relevant high current conditions is limited by the weak interaction between isolated Ni-N sites and *COOH intermediates, restricting efficient CO conversion. Here, we introduced edge-rich Ni-N sites via support vacancy engineering to enhance *COOH adsorption, thereby boosting the CORR activity and selectivity in acidic media.
View Article and Find Full Text PDF