98%
921
2 minutes
20
A new method for the preconcentration of some trace metals (Co, Ni, Cu, and Cd) as complexed with ammonium pyrrolidynedithiocarbamate (APDC) was developed using a mini-column filled with Amberlite XAD-2000 resin. Metal contents were determined by flame atomic absorption spectrometry (FAAS) after the metal complexes accumulated on the resin were eluted with 1M HNO(3) in acetone. The effects of the analytical parameters such as sample pH, quantity of complexing agent, eluent type, resin quantity, sample volume, sample flow rate, and matrix ions were investigated on the recovery of the metals from aqueous solutions. The relative standard deviation (R.S.D.) of the method was <6%. The validation of the method was confirmed using two certified reference materials (CRM TMDW-500 Drinking Water and CRM SA-C Sandy Soil C). The method was successfully applied to some stream waters and mushroom samples from Eastern Black Sea Region (Trabzon city) of Turkey.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jhazmat.2008.05.034 | DOI Listing |
Talanta
January 2010
Department of Chemistry, Faculty of Sciences, K.N. Toosi University of Technology, Tehran 16617, Iran.
A new solid phase extraction method for separation and preconcentration of trace amounts of uranium, thorium, and zirconium in water samples is proposed. The procedure is based on the adsorption of U(VI), Th(IV) and Zr(IV) ions on a column of Amberlite XAD-2000 resin loaded with alpha-benzoin oxime prior to their simultaneous spectrophotometric determination with Arsenazo III using orthogonal signal correction partial least squares method. The enrichment factor for preconcentration of uranium, thorium, and zirconium was found to be 100.
View Article and Find Full Text PDFJ Hazard Mater
February 2009
Department of Chemistry, Karadeniz Technical University, 61080 Trabzon, Turkey.
A new method for the preconcentration of some trace metals (Co, Ni, Cu, and Cd) as complexed with ammonium pyrrolidynedithiocarbamate (APDC) was developed using a mini-column filled with Amberlite XAD-2000 resin. Metal contents were determined by flame atomic absorption spectrometry (FAAS) after the metal complexes accumulated on the resin were eluted with 1M HNO(3) in acetone. The effects of the analytical parameters such as sample pH, quantity of complexing agent, eluent type, resin quantity, sample volume, sample flow rate, and matrix ions were investigated on the recovery of the metals from aqueous solutions.
View Article and Find Full Text PDFJ Hazard Mater
May 2008
Chemistry Department, Science and Arts Faculty, Pamukkale University, Denizli, Turkey.
This work describes a procedure for the separation-preconcentration of Fe(III), Pb(II) and Cr(III) from some water samples using a column-filled Amberlite XAD-2000 resin. The analyte ions retained on the column were eluted with 0.5 mol L(-1) HNO(3).
View Article and Find Full Text PDFJ Hazard Mater
March 2008
Dokuz Eylul University, Faculty of Sciences and Arts, Chemistry Department, Izmir, Turkey.
The impregnation of o-phenylene dioxydiacetic acid (OPDA) into a polymeric matrix, Amberlite XAD-2000, is reported and was characterized by infrared spectroscopy. The amount of attached OPDA to the polymer resin was found to be 1.77mmolg(-1) resin.
View Article and Find Full Text PDFJ Hazard Mater
October 2007
Department of Chemistry, Faculty of Arts & Sciences, Karadeniz Technical University, 61080 Trabzon, Turkey.
A simple and accurate method was developed for separation and enrichment of trace levels of gold in environmental samples. The method is based on the adsorption of Au(III)-diethyldithiocarbamate complex on Amberlite XAD-2000 resin prior to the analysis of gold by flame atomic absorption spectrometry after elution with 1 molL(-1) HNO3 in acetone. Some parameters including nitric acid concentration, eluent type, matrix ions, sample volume, sample flow rate and adsorption capacity were investigated on the recovery of gold(III).
View Article and Find Full Text PDF