A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Well-less capillary array electrophoresis chip using hydrophilic sample bridges. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

An innovative sample introduction method that facilitates extreme simplification of the layout of a capillary array electrophoresis (CAE) chip is described. Multiple samples were directly injected onto CAE channels from sample loaders using hydrophilic sample bridges, thus obviating auxiliary components of sample wells and sampling channels of a typical CAE chip. Hydrophilic sample bridges were spontaneously formed in hydrophobic surroundings to connect sample loaders to corresponding CAE channels, through which electrosample injections were effectively made. Sample dispersion was intrinsically avoided due to the "sticky" nature of the bridges. Utilizing hydrophilic interactions, target spots for formation of sample bridges can be expanded from the actual openings of CAE channels, which reduces the burden of precise positioning of samples toward CAE channels. In this work, simultaneous introduction of multiple samples onto well-less CAE channels arranged with 1-mm gaps was successfully demonstrated. Well-less CAE chips, feasible now due to the hydrophilic sample bridges, would bring unprecedented advantages in both production and operation because of their extreme simplicity.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac071115pDOI Listing

Publication Analysis

Top Keywords

sample bridges
20
cae channels
20
hydrophilic sample
16
sample
10
capillary array
8
array electrophoresis
8
chip hydrophilic
8
cae
8
cae chip
8
multiple samples
8

Similar Publications